paper

Kinetic Inductance Magnetometer

arXiv:1401.0668 · doi:10.1038/ncomms5872

Abstract

Ultrasensitive magnetic field detection is utilized in the fields of science, medicine and industry. We report on a novel magnetometer relying on the kinetic inductance of superconducting material. The kinetic inductance exhibits a non-linear response with respect to DC current, a fact that is exploited by applying magnetic flux through a superconducting loop to generate a shielding current and a change in the inductance of the loop. The magnetometer is arranged into a resonator, allowing readout through a transmission measurement that makes the device compatible with radio frequency multiplexing techniques. The device is fabricated using a single thin-film layer of NbN, simplifying the fabrication process compared to existing magnetometer technologies considerably. Our experimental data, supported by theory, demonstrates a magnetometer having potential to replace established technology in applications requiring ultra-high sensitivity.

16 pages, 6 figures

References in corpus (3)

Cited by in corpus (24)