High Resolution Gamma Ray Detection in a Dual Phase Xenon Time Projection Chamber
arXiv:1309.5561 · doi:10.1088/1748-0221/9/04/P04014
Abstract
Dual phase Xenon Time Projection Chambers (XeTPCs) are being used by several experiments as a promising technique for direct detection of dark matter. We report on the design and performance of a small 3-D sensitive dual phase XeTPC. The position resolution is 2 mm in the center of detector, limited by the hole size of the mesh at the proportional scintillation region. An energy resolution of 1.6%(σ /E) for 662 keV gamma rays is achieved by combining the ionization and scintillation signals at a drift field of 0.5 kV/cm. This represents the best energy resolution achieved among liquid xenon detectors. The energy resolution is only slightly dependent on drift field. Better than 2% energy resolution (σ /E) for 662 keV gamma rays can be achieved for drift fields between 100 V/cm and 2 kV/cm. With high position and energy resolutions, a dual phase XeTPC has also potential applications in surveys for neutrinoless double-beta decay and in gamma ray imaging.
References in corpus (19)
- First results from the LUX dark matter experiment at the Sanford Underground Research Facility
- Dark Matter Results from 225 Live Days of XENON100 Data
- First Results from the XENON10 Dark Matter Experiment at the Gran Sasso National Laboratory
- Search for Neutrinoless Double-Beta Decay in Xe with EXO-200
- The XENON100 Dark Matter Experiment
- Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
- An improved measurement of the 2νββ half-life of Xe-136 with EXO-200
- Simultaneous Measurement of Ionization and Scintillation from Nuclear Recoils in Liquid Xenon as Target for a Dark Matter Experiment
- First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase xenon detector for dark matter detection
- The EXO-200 detector, part I: Detector design and construction
- Observation and applications of single-electron charge signals in the XENON100 experiment
- Observation of Anti-correlation between Scintillation and Ionization for MeV Gamma-Rays in Liquid Xenon
- Characterization of the Hamamatsu R11410-10 3-Inch Photomultiplier Tube for Liquid Xenon Dark Matter Direct Detection Experiments
- Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering
- XAX: a multi-ton, multi-target detection system for dark matter, double beta decay and pp solar neutrinos
- Preparation of Neutron-activated Xenon for Liquid Xenon Detector Calibration
- A Study of the LXeGRIT Detection Efficiency for MeV Gamma-Rays during the 2000 Balloon Flight Campaign
- Xenon Recirculation-Purification with a Heat Exchanger
- Spectroscopy and Imaging Performance of the Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT)
Cited by in corpus (5)
- Characterization of alpha and beta interactions in liquid xenon
- Scintillation and Ionization Responses of Liquid Xenon to Low Energy Electronic and Nuclear Recoils at Drift Fields from 236 V/cm to 3.93 kV/cm
- MiX: A Position Sensitive Dual-Phase Liquid Xenon Detector
- Development and Performance of a Sealed Liquid Xenon Time Projection Chamber
- Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions