Xenon Recirculation-Purification with a Heat Exchanger
arXiv:1103.0986 · doi:10.1088/1748-0221/6/03/P03002
Abstract
Liquid-xenon based particle detectors have been dramatically growing in size during the last years, and are now exceeding the one-ton scale. The required high xenon purity is usually achieved by continuous recirculation of xenon gas through a high-temperature getter. This challenges the traditional way of cooling these large detectors, since in a thermally well insulated detector, most of the cooling power is spent to compensate losses from recirculation. The phase change during recondensing requires five times more cooling power than cooling the gas from ambient temperature to -100C (173 K). Thus, to reduce the cooling power requirements for large detectors, we propose to use the heat from the purified incoming gas to evaporate the outgoing xenon gas, by means of a heat exchanger. Generally, a heat exchanger would appear to be only of very limited use, since evaporation and liquefaction occur at zero temperature difference. However, the use of a recirculation pump reduces the pressure of the extracted liquid, forces it to evaporate, and thus cools it down. We show that this temperature difference can be used for an efficient heat exchange process. We investigate the use of a commercial parallel plate heat exchanger with a small liquid xenon detector. Although we expected to be limited by the available cooling power to flow rates of about 2 SLPM, rates in excess of 12 SLPM can easily be sustained, limited only by the pump speed and the impedance of the flow loop. The heat exchanger operates with an efficiency of (96.8 +/- 0.5)%. This opens the possibility for fast xenon gas recirculation in large-scale experiments, while minimizing thermal losses.
10 pages, 3 figures
References in corpus (4)
- First Dark Matter Results from the XENON100 Experiment
- Simultaneous Measurement of Ionization and Scintillation from Nuclear Recoils in Liquid Xenon as Target for a Dark Matter Experiment
- A limit for the mu -> e gamma decay from the MEG experiment
- New Measurement of the Relative Scintillation Efficiency of Xenon Nuclear Recoils Below 10 keV
Cited by in corpus (12)
- DARWIN: towards the ultimate dark matter detector
- New Measurement of the Scintillation Efficiency of Low-Energy Nuclear Recoils in Liquid Xenon
- Removing krypton from xenon by cryogenic distillation to the ppq level
- Measurement of the Scintillation Yield of Low-Energy Electrons in Liquid Xenon
- A Rn-220 source for the calibration of low-background experiments
- The Cryogenic System for the Panda-X Dark Matter Search Experiment
- MiX: A Position Sensitive Dual-Phase Liquid Xenon Detector
- Performance of a cryogenic system prototype for the XENON1T Detector
- The LUX Prototype Detector: Heat Exchanger Development
- Design and construction of Xenoscope -- a full-scale vertical demonstrator for the DARWIN observatory
- High Resolution Gamma Ray Detection in a Dual Phase Xenon Time Projection Chamber
- The distributed Slow Control System of the XENON100 Experiment