Performance of a cryogenic system prototype for the XENON1T Detector
arXiv:1208.2001 · doi:10.1088/1748-0221/7/10/P10001
Abstract
We have developed an efficient cryogenic system with heat exchange and associated gas purification system, as a prototype for the XENON1T experiment. The XENON1T detector will use about 3 ton of liquid xenon (LXe) at a temperature of 175K as target and detection medium for a dark matter search. In this paper we report results on the cryogenic system performance focusing on the dynamics of the gas circulation-purification through a heated getter, at flow rates above 50 Standard Liter per Minute (SLPM). A maximum flow of 114 SLPM has been achieved, and using two heat exchangers in parallel, a heat exchange efficiency better than 96% has been measured.
References in corpus (6)
- Dark Matter Results from 100 Live Days of XENON100 Data
- The XENON100 Dark Matter Experiment
- Liquid Xenon Detectors for Particle Physics and Astrophysics
- Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200
- Absorption of Scintillation Light in a 100 Liquid Xenon Ray Detector and Expected Detector Performance
- Xenon Recirculation-Purification with a Heat Exchanger
Cited by in corpus (9)
- DARWIN: towards the ultimate dark matter detector
- The XENON1T Dark Matter Experiment
- Liquid-phase purification for multi-tonne xenon detectors
- A Rn-220 source for the calibration of low-background experiments
- The Cryogenics and Xenon handling system for the PandaX-4T Experiment
- High Voltage in Noble Liquids for High Energy Physics
- Design and construction of Xenoscope -- a full-scale vertical demonstrator for the DARWIN observatory
- A LN2-based cryogenic system prototype for future PandaX experiment
- Design, construction, and testing of the PandaX-xT cryogenics system