Precise Measurement of Laser Power using an Optomechanical System
arXiv:1309.4779 · doi:10.1364/OE.22.002013
Abstract
This paper shows a novel method to precisely measure the laser power using an optomechanical system. By measuring a mirror displacement caused by the reflection of an amplitude modulated laser beam, the number of photons in the incident continuous-wave laser can be precisely measured. We have demonstrated this principle by means of a prototype experiment uses a suspended 25 mg mirror as an mechanical oscillator coupled with the radiation pressure and a Michelson interferometer as the displacement sensor. A measurement of the laser power with an uncertainty of less than one percent (1 sigma) is achievable.
arXiv comment18 pages, 11 figures, published in Optics Express
References in corpus (4)
- Conversion of conventional gravitational-wave interferometers into QND interferometers by modifying their input and/or output optics
- Observation of squeezed light with 10dB quantum noise reduction
- Quantum Metrology for Gravitational Wave Astronomy
- Photon pressure induced test mass deformation in gravitational-wave detectors