Investigation of gamma-ray sensitivity of neutron detectors based on thin converter films
arXiv:1306.6247 · doi:10.1088/1748-0221/8/10/P10025
Abstract
Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare 3He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have been proposed as an appropriate choice for applications where large area coverage is necessary. In this paper, we investigate the probability for gamma-rays to generate a false count in a neutron measurement. Simulated results are compared to measurement with a 10B thin film prototype and a 3He detector. It is demonstrated that equal gamma-ray rejection to that of 3He tubes is achieved with the new technology. The arguments and results presented here are also applicable to gas detectors with converters other than solid 10B layers, such as 6Li layers and 10BF3 gas.
Submitted to Journal of Instrumentation
References in corpus (1)
Cited by in corpus (21)
- The Multi-Blade Boron-10-based Neutron Detector for high intensity Neutron Reflectometry at ESS
- Multi-Grid Detector for Neutron Spectroscopy: Results Obtained on Time-of-Flight Spectrometer CNCS
- Neutron detectors for the ESS diffractometers
- Characterization of the silicon+6LiF thermal neutron detection technique
- Characterization of Thermal Neutron Beam Monitors
- Fast neutron sensitivity of neutron detectors based on boron-10 converter layers
- Characterization of the Multi-Blade 10B-based detector at the CRISP reflectometer at ISIS for neutron reflectometry at ESS
- Novel Boron-10-based detectors for Neutron Scattering Science
- Scattered neutron background in thermal neutron detectors
- Boron-10 layers, Neutron Reflectometry and Thermal Neutron Gaseous Detectors
- Overcoming High Energy Backgrounds at Pulsed Spallation Sources
- Evidence of fast neutron sensitivity for 3He detectors and comparison with Boron-10 based neutron detectors
- Performance evaluation of the Boron Coated Straws detector with Geant4
- Verification of He-3 proportional counters fast neutron sensitivity through a comparison with He-4 detectors
- Investigation of background in large-area neutron detectors due to alpha emission from impurities in aluminium
- Neutron reflectometry on highly absorbing films and its application to 10B4C-based neutron detectors
- Feasibility of Neutron Coincidence Counting for Spent Fuel
- Suppression of intrinsic neutron background in the Multi-Grid detector
- Time- and energy-resolved effects in the boron-10 based Multi-Grid and helium-3 based thermal neutron detectors
- Multitube monitors: a new-generation of neutron beam monitors
- Neutron activation and prompt gamma intensity in Ar/CO-filled neutron detectors at the European Spallation Source