Fast neutron sensitivity of neutron detectors based on boron-10 converter layers
arXiv:1712.05614 · doi:10.1088/1748-0221/13/03/P03004
Abstract
In the last few years many detector technologies for thermal neutron detection have been developed in order to face the shortage of 3He, which is now much less available and more expensive. Moreover the 3He-based detectors can not fulfil the requirements in performance, e.g. the spatial resolution and the counting rate capability needed for the new instruments. The Boron-10-based gaseous detectors have been proposed as a suitable choice. This and other alternatives technologies are being developed at ESS. Higher intensities mean higher signals but higher background as well. The signal-to-background ratio is an important feature to study, in particular the gamma-ray and the fast neutron contributions. This paper investigates, for the first time, the fast neutrons sensitivity of 10B-based thermal neutron detector. It presents the study of the detector response as a function of energy threshold and the underlying physical mechanisms. The latter are explained with the help of theoretical considerations and simulations.
References in corpus (5)
- The Multi-Blade Boron-10-based Neutron Detector for high intensity Neutron Reflectometry at ESS
- Analytical modeling of thin film neutron converters and its application to thermal neutron gas detectors
- Multi-Grid Detector for Neutron Spectroscopy: Results Obtained on Time-of-Flight Spectrometer CNCS
- First Measurements with New High-Resolution Gadolinium-GEM Neutron Detectors
- A comparison of untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe sources
Cited by in corpus (12)
- NCrystal : a library for thermal neutron transport
- Characterization of the Multi-Blade 10B-based detector at the CRISP reflectometer at ISIS for neutron reflectometry at ESS
- Scattered neutron background in thermal neutron detectors
- Neutron reflectometry with the Multi-Blade 10B-based detector
- Performance evaluation of the Boron Coated Straws detector with Geant4
- Evidence of fast neutron sensitivity for 3He detectors and comparison with Boron-10 based neutron detectors
- Verification of He-3 proportional counters fast neutron sensitivity through a comparison with He-4 detectors
- The Multi-Blade Boron-10-based neutron detector performance using a focusing reflectometer
- Suppression of intrinsic neutron background in the Multi-Grid detector
- Multi-Blade detector with VMM3a-ASIC-based readout: installation and commissioning at the reflectometer Amor at PSI
- Investigation of neutron scattering in the Multi-Blade detector with Geant4 simulations
- Self-Shielding Copper Substrate Neutron Supermirror Guides