Automated Calibration System for a High-Precision Measurement of Neutrino Mixing Angle with the Daya Bay Antineutrino Detectors
arXiv:1305.2248 · doi:10.1016/j.nima.2014.02.049
Abstract
We describe the automated calibration system for the antineutrino detectors in the Daya Bay Neutrino Experiment. This system consists of 24 identical units instrumented on 8 identical 20-ton liquid scintillator detectors. Each unit is a fully automated robotic system capable of deploying an LED and various radioactive sources into the detector along given vertical axes. Selected results from performance studies of the calibration system are reported.
References in corpus (14)
- Observation of electron-antineutrino disappearance at Daya Bay
- Observation of Reactor Electron Antineutrino Disappearance in the RENO Experiment
- Indication of Electron Neutrino Appearance from an Accelerator-produced Off-axis Muon Neutrino Beam
- Indication for the disappearance of reactor electron antineutrinos in the Double Chooz experiment
- Search for neutrino oscillations on a long base-line at the CHOOZ nuclear power station
- Improved search for muon-neutrino to electron-neutrino oscillations in MINOS
- The Sudbury Neutrino Observatory
- Reactor electron antineutrino disappearance in the Double Chooz experiment
- Improved Measurement of Electron Antineutrino Disappearance at Daya Bay
- Results from the Palo Verde Neutrino Oscillation Experiment
- Spectral measurement of electron antineutrino oscillation amplitude and frequency at Daya Bay
- A side-by-side comparison of Daya Bay antineutrino detectors
- Neutrino Masses and Oscillations: Triumphs and Challenges
- Acrylic Target Vessels for a High-Precision Measurement of theta13 with the Daya Bay Antineutrino Detectors
Cited by in corpus (26)
- A new measurement of antineutrino oscillation with the full detector configuration at Daya Bay
- Measurement of electron antineutrino oscillation based on 1230 days of operation of the Daya Bay experiment
- Improved Measurement of the Reactor Antineutrino Flux and Spectrum at Daya Bay
- The Detector System of The Daya Bay Reactor Neutrino Experiment
- Calibration Strategy of the JUNO Experiment
- Improved Search for a Light Sterile Neutrino with the Full Configuration of the Daya Bay Experiment
- Improved Measurement of the Reactor Antineutrino Flux at Daya Bay
- New measurement of via neutron capture on hydrogen at Daya Bay
- Physics with Reactor Neutrinos
- Reactor Neutrino Experiments: Present and Future
- Neutrino mass hierarchy determination and other physics potential of medium-baseline reactor neutrino oscillation experiments
- Determination of the total absorption peak in an electromagnetic calorimeter
- Neutron Calibration Sources in the Daya Bay Experiment
- Cable Loop Calibration System for Jiangmen Underground Neutrino Observatory
- A new method of energy reconstruction for large spherical liquid scintillator detectors
- Calibration Strategy of the JUNO-TAO Experiment
- Manual Calibration System for Daya Bay Reactor Neutrino Experiment
- The Automatic Calibration Unit in JUNO
- JUNO Physics and Detector
- Performance of the 1-ton Prototype Neutrino Detector at CJPL-I
- Generative Adversarial Networks for Scintillation Signal Simulation in EXO-200
- Reactor Neutrino Experiments: and Beyond
- Background Evaluation for the Neutron Sources in the Daya Bay Experiment
- A Precise Method to Determine the Energy Scale and Resolution using Gamma Calibration Sources in a Liquid Scintillator Detector
- A high precision calibration of the nonlinear energy response at Daya Bay
- A Decade of Discoveries by the Daya Bay Reactor Neutrino Experiment