Redundancy Calibration of Phased Array Stations
arXiv:1205.1413 · doi:10.1051/0004-6361/201219087
Abstract
Our aim is to assess the benefits and limitations of using the redundant visibility information in regular phased array systems for improving the calibration. Regular arrays offer the possibility to use redundant visibility information to constrain the calibration of the array independent of a sky model and a beam models of the station elements. It requires a regular arrangement in the configuration of array elements and identical beam patterns. We revised a calibration method for phased array stations using the redundant visibility information in the system and applied it successfully to a LOFAR station. The performance and limitations of the method were demonstrated by comparing its use on real and simulated data. The main limitation is the mutual coupling between the station elements, which leads to non-identical beams and stronger baseline dependent noise. Comparing the variance of the estimated complex gains with the Cramer-Rao Bound (CRB) indicates that redundancy is a stable and optimum method for calibrating the complex gains of the system. Our study shows that the use of the redundant visibility does improve the quality of the calibration in phased array systems. In addition it provides a powerful tool for system diagnostics. Our results demonstrate that designing redundancy in both the station layout and the array configuration of future aperture arrays is strongly recommended. In particular in the case of the Square Kilometre Array with its dynamic range requirement which surpasses any existing array by an order of magnitude.
16 pages, 15 figures, accepted for publication in the A&A in Section 13, acceptance date: 1st May 2012. NOTE: Please contact the first author for high resolution figures
References in corpus (3)
Cited by in corpus (12)
- PAPER-64 Constraints on Reionization: The 21cm Power Spectrum at z=8.4
- Calibration Requirements for Detecting the 21 cm Epoch of Reionization Power Spectrum and Implications for the SKA
- MITEoR: A Scalable Interferometer for Precision 21 cm Cosmology
- Comparing Redundant and Sky Model Based Interferometric Calibration: A First Look with Phase II of the MWA
- Calibrating CHIME, A New Radio Interferometer to Probe Dark Energy
- Polarized Redundant-Baseline Calibration for 21 cm Cosmology Without Adding Spectral Structure
- The Bias and Uncertainty of Redundant and Sky-Based Calibration under Realistic Sky and Telescope Conditions
- Characterization of a dense aperture array for radio astronomy
- Redundant interferometric calibration as a complex optimization problem
- Calibration Schemes with Scaling for Large-N Radio Interferometers Built on a Regular Grid
- Mapping our Universe in 3D with MITEoR
- It's Always Darkest Before the Cosmic Dawn: Early Results from Novel Tools and Telescopes for 21 cm Cosmology