Plasma effect in Silicon Charge Coupled Devices (CCDs)
arXiv:1105.3229 · doi:10.1016/j.nima.2011.10.060
Abstract
Plasma effect is observed in CCDs exposed to heavy ionizing alpha-particles with energies in the range 0.5 - 5.5 MeV. The results obtained for the size of the charge clusters reconstructed on the CCD pixels agrees with previous measurements in the high energy region (>3.5 MeV). The measurements were extended to lower energies using alpha-particles produced by (n,alpha) reactions of neutrons in a Boron-10 target. The effective linear charge density for the plasma column is measured as a function of energy. The results demonstrate the potential for high position resolution in the reconstruction of alpha particles, which opens an interesting possibility for using these detectors in neutron imaging applications.
References in corpus (1)
Cited by in corpus (8)
- Charge Coupled Devices for detection of coherent neutrino-nucleus scattering
- Measurement of radioactive contamination in the high-resistivity silicon CCDs of the DAMIC experiment
- Measurement of camera image sensor depletion thickness with cosmic rays
- Measurement of the bulk radioactive contamination of detector-grade silicon with DAMIC at SNOLAB
- The DAMIC dark matter experiment
- A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)
- Fat cosmic ray tracks in charge-coupled devices
- PSF-like Alpha-Particle Events in LSST Images