3D tumor localization through real-time volumetric x-ray imaging for lung cancer radiotherapy
arXiv:1102.1712 · doi:10.1118/1.3582693
Abstract
Recently we have developed an algorithm for reconstructing volumetric images and extracting 3D tumor motion information from a single x-ray projection. We have demonstrated its feasibility using a digital respiratory phantom with regular breathing patterns. In this work, we present a detailed description and a comprehensive evaluation of the improved algorithm. The algorithm was improved by incorporating respiratory motion prediction. The accuracy and efficiency were then evaluated on 1) a digital respiratory phantom, 2) a physical respiratory phantom, and 3) five lung cancer patients. These evaluation cases include both regular and irregular breathing patterns that are different from the training dataset. For the digital respiratory phantom with regular and irregular breathing, the average 3D tumor localization error is less than 1 mm. On an NVIDIA Tesla C1060 GPU card, the average computation time for 3D tumor localization from each projection ranges between 0.19 and 0.26 seconds, for both regular and irregular breathing, which is about a 10% improvement over previously reported results. For the physical respiratory phantom, an average tumor localization error below 1 mm was achieved with an average computation time of 0.13 and 0.16 seconds on the same GPU card, for regular and irregular breathing, respectively. For the five lung cancer patients, the average tumor localization error is below 2 mm in both the axial and tangential directions. The average computation time on the same GPU card ranges between 0.26 and 0.34 seconds.
References in corpus (4)
- Implementation and evaluation of various demons deformable image registration algorithms on GPU
- A patient-specific respiratory model of anatomical motion for radiation treatment planning
- Real-time volumetric image reconstruction and 3D tumor localization based on a single x-ray projection image for lung cancer radiotherapy
- PCA-based lung motion model
Cited by in corpus (5)
- PCA-based lung motion model
- A method for real-time volumetric imaging in radiotherapy using single x-ray projection
- Real-time non-rigid 3D respiratory motion estimation for MR-guided radiotherapy using MR-MOTUS
- Cine cone beam CT reconstruction using low-rank matrix factorization: algorithm and a proof-of-princple study
- Dynamic CBCT Imaging using Prior Model-Free Spatiotemporal Implicit Neural Representation (PMF-STINR)