Implementation and evaluation of various demons deformable image registration algorithms on GPU
arXiv:0909.0928 · doi:10.1088/0031-9155/55/1/012
Abstract
Online adaptive radiation therapy (ART) promises the ability to deliver an optimal treatment in response to daily patient anatomic variation. A major technical barrier for the clinical implementation of online ART is the requirement of rapid image segmentation. Deformable image registration (DIR) has been used as an automated segmentation method to transfer tumor/organ contours from the planning image to daily images. However, the current computational time of DIR is insufficient for online ART. In this work, this issue is addressed by using computer graphics processing units (GPUs). A grey-scale based DIR algorithm called demons and five of its variants were implemented on GPUs using the Compute Unified Device Architecture (CUDA) programming environment. The spatial accuracy of these algorithms was evaluated over five sets of pulmonary 4DCT images with an average size of 256x256x100 and more than 1,100 expert-determined landmark point pairs each. For all the testing scenarios presented in this paper, the GPU-based DIR computation required around 7 to 11 seconds to yield an average 3D error ranging from 1.5 to 1.8 mm. It is interesting to find out that the original passive force demons algorithms outperform subsequently proposed variants based on the combination of accuracy, efficiency, and ease of implementation.
arXiv commentSubmitted to Physics in Medicine and Biology
References in corpus (2)
Cited by in corpus (27)
- GPU-based Low Dose CT Reconstruction via Edge-preserving Total Variation Regularization
- GPU-based fast Monte Carlo simulation for radiotherapy dose calculation
- GPU-based Iterative Cone Beam CT Reconstruction Using Tight Frame Regularization
- Real-time volumetric image reconstruction and 3D tumor localization based on a single x-ray projection image for lung cancer radiotherapy
- A GPU Tool for Efficient, Accurate, and Realistic Simulation of Cone Beam CT Projections
- Development of a GPU-based Monte Carlo dose calculation code for coupled electron-photon transport
- Multi-GPU Accelerated Multi-Spin Monte Carlo Simulations of the 2D Ising Model
- 3D tumor localization through real-time volumetric x-ray imaging for lung cancer radiotherapy
- Ultra-fast treatment plan optimization for volumetric modulated arc therapy (VMAT)
- GPU-based ultra-fast direct aperture optimization for online adaptive radiation therapy
- Four-dimensional Cone Beam CT Reconstruction and Enhancement using a Temporal Non-Local Means Method
- Fast Monte Carlo Simulation for Patient-specific CT/CBCT Imaging Dose Calculation
- A GPU implementation of a track-repeating algorithm for proton radiotherapy dose calculations
- GPU-based fast gamma index calcuation
- A Contour-Guided Deformable Image Registration Algorithm for Adaptive Radiotherapy
- PDE-constrained optimization in medical image analysis
- A method for real-time volumetric imaging in radiotherapy using single x-ray projection
- A GPU-based finite-size pencil beam algorithm with 3D-density correction for radiotherapy dose calculation
- Fast GPU 3D Diffeomorphic Image Registration
- Optimal Surface Marker Locations for Tumor Motion Estimation in Lung Cancer Radiotherapy
- Registration-Guided Deep Learning Image Segmentation for Cone Beam CT-based Online Adaptive Radiotherapy
- Deep Learning based Direct Segmentation Assisted by Deformable Image Registration for Cone-Beam CT based Auto-Segmentation for Adaptive Radiotherapy
- Segmentation by Test-Time Optimization (TTO) for CBCT-based Adaptive Radiation Therapy
- Multi-Node Multi-GPU Diffeomorphic Image Registration for Large-Scale Imaging Problems
- GPU-based Fast Low-dose Cone Beam CT Reconstruction via Total Variation
- Multimodal image registration for effective thermographic fever screening
- Continuous Generation of Volumetric Images During Stereotactic Body Radiation Therapy Using Periodic kV Imaging and an External Respiratory Surrogate