Size scaling of strength in thin film delamination
arXiv:1101.0824 · doi:10.1088/1742-5468/2011/02/P02024
Abstract
We investigate by numerical simulation the system size dependence of the shear delamination strength of thin elastic films. The films are connected to a rigid substrate by a disordered interface containing a pre-existing crack. The size dependence of the strength of this system is found to depend crucially on the crack shape. For circular cracks, we observe a crossover between a size-independent regime at large crack radii which is controlled by propagation of the pre-existing crack, and a size-dependent regime at small radii which is dominated by nucleation of new cracks in other locations. For cracks of finite width that span the system transversally, we observe for all values of the crack length a logarithmic system size dependence of the failure stress. The results are interpreted in terms of extreme value statistics.
arXiv comment10 pages, 4 figures
References in corpus (6)
- Statistical Models of Fracture
- Role of disorder in the size-scaling of material strength
- Morphology of two dimensional fracture surface
- Planar cracks in the fuse model
- Nucleation of interfacial shear cracks in thin films on disordered substrates
- Roughening and pinning of interface cracks in shear delamination of thin films