Abstract
Direct comparisons between statistically sound simulations of ion-tracks and published experimental measurements of range densities of iodine implants in uranium dioxide have been made with implant energies in the range of 100-800 keV. Our simulations are conducted with REED-MD (Rare Event Enhanced Domain-following Molecular Dynamics) in order to account for the materials structure in both single crystalline and polycrystalline experimental samples. We find near-perfect agreement between REED-MD results and experiments for polycrystalline target materials.
arXiv commentEleven pages, four figures.
References in corpus (5)
- An Efficient Molecular Dynamics Scheme for the Calculation of Dopant Profiles due to Ion Implantation
- A phenomenological electronic stopping power model for molecular dynamics and Monte Carlo simulation of ion implantation into silicon
- Simulation of phosphorus implantation into silicon with a single-parameter electronic stopping power model
- An Efficient Molecular Dynamics Scheme for Predicting Dopant Implant Profiles in Semiconductors
- Efficient Parallel Algorithm for Statistical Ion Track Simulations in Crystalline Materials