PCA-based lung motion model
arXiv:1002.0033 · doi:10.1088/0031-9155/56/18/015
Abstract
Organ motion induced by respiration may cause clinically significant targeting errors and greatly degrade the effectiveness of conformal radiotherapy. It is therefore crucial to be able to model respiratory motion accurately. A recently proposed lung motion model based on principal component analysis (PCA) has been shown to be promising on a few patients. However, there is still a need to understand the underlying reason why it works. In this paper, we present a much deeper and detailed analysis of the PCA-based lung motion model. We provide the theoretical justification of the effectiveness of PCA in modeling lung motion. We also prove that under certain conditions, the PCA motion model is equivalent to 5D motion model, which is based on physiology and anatomy of the lung. The modeling power of PCA model was tested on clinical data and the average 3D error was found to be below 1 mm.
4 pages, 1 figure. submitted to International Conference on the use of Computers in Radiation Therapy 2010
References in corpus (3)
- A patient-specific respiratory model of anatomical motion for radiation treatment planning
- Real-time volumetric image reconstruction and 3D tumor localization based on a single x-ray projection image for lung cancer radiotherapy
- 3D tumor localization through real-time volumetric x-ray imaging for lung cancer radiotherapy
Cited by in corpus (9)
- Real-time volumetric image reconstruction and 3D tumor localization based on a single x-ray projection image for lung cancer radiotherapy
- 3D tumor localization through real-time volumetric x-ray imaging for lung cancer radiotherapy
- A method for real-time volumetric imaging in radiotherapy using single x-ray projection
- Real-time non-rigid 3D respiratory motion estimation for MR-guided radiotherapy using MR-MOTUS
- Real-Time 2D-3D Deformable Registration with Deep Learning and Application to Lung Radiotherapy Targeting
- Dynamic Cone-beam CT Reconstruction using Spatial and Temporal Implicit Neural Representation Learning (STINR)
- Frame forecasting in cine MRI using the PCA respiratory motion model: comparing recurrent neural networks trained online and transformers
- Rank Constrained Diffeomorphic Density Motion Estimation for Respiratory Correlated Computed Tomography
- Continuous Generation of Volumetric Images During Stereotactic Body Radiation Therapy Using Periodic kV Imaging and an External Respiratory Surrogate