TRIGA-SPEC: A setup for mass spectrometry and laser spectroscopy at the research reactor TRIGA Mainz
arXiv:0805.4475 · doi:10.1016/j.nima.2008.06.023
Abstract
The research reactor TRIGA Mainz is an ideal facility to provide neutron-rich nuclides with production rates sufficiently large for mass spectrometric and laser spectroscopic studies. Within the TRIGA-SPEC project, a Penning trap as well as a beam line for collinear laser spectroscopy are being installed. Several new developments will ensure high sensitivity of the trap setup enabling mass measurements even on a single ion. Besides neutron-rich fission products produced in the reactor, also heavy nuclides such as 235-U or 252-Cf can be investigated for the first time with an off-line ion source. The data provided by the mass measurements will be of interest for astrophysical calculations on the rapid neutron-capture process as well as for tests of mass models in the heavy-mass region. The laser spectroscopic measurements will yield model-independent information on nuclear ground-state properties such as nuclear moments and charge radii of neutron-rich nuclei of refractory elements far from stability. This publication describes the experimental setup as well as its present status.
arXiv comment20 pages, 17 figures
References in corpus (3)
Cited by in corpus (19)
- A White Paper on keV Sterile Neutrino Dark Matter
- Precision Atomic Physics Techniques for Nuclear Physics with Radioactive Beams
- Direct Measurement of the Mass Difference of Ho163 and Dy163 Solves the Q-Value Puzzle for the Neutrino Mass Determination
- Penning traps as a versatile tool for precise experiments in fundamental physics
- The Electron Capture Ho Experiment ECHo: an overview
- Measurements of neutron-induced reactions in inverse kinematics
- Neutrinoless Double-Electron Capture
- Verifying the accuracy of the TITAN Penning-trap mass spectrometer
- Perspectives on testing fundamental physics with highly charged ions in Penning traps
- Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy
- Position-sensitive ion detection in precision Penning trap mass spectrometry
- Q value and half-life of double-electron capture in Os-184
- The TRAPSENSOR Facility: an Open-Ring 7-Tesla Penning Trap for Laser-Based Precision Experiments
- High-accuracy Penning trap mass measurements with stored and cooled exotic ions
- High-precision mass measurement of doubly magic Pb
- Direct mass measurements of cadmium and palladium isotopes and their double-beta transition Q-values
- Plastic Scintillation Detectors for Time-of-Flight Mass Measurements
- Electric and magnetic field optimization procedure for Penning trap mass spectrometers
- Fast Silicon Carbide MOSFET based high-voltage push-pull switch for charge state separation of highly charged ions with a Bradbury-Nielsen Gate