123 citations · 828 across the 28 of their papers we have counts for
30 papers
A Cryogenic Penning Trap Based on Permanent Magnets
F. Völksen, K. K. Anjum, R. P. Czampiel +30
We report on a Penning trap based on NdFeB permanent magnets operated at 4\,K with a magnetic field strength of 280\,mT. Reliable loading and confinement of protons, H ions,…
Trapping of electrons and ions in a dual-frequency Paul trap
Vladimir Mikhailovskii, Natalija Sheth, Guofeng Qu +12
We demonstrate the operation of a dual-frequency Paul trap and characterize its performance by storing either electrons or calcium ions while applying two quadrupole fields simulta…
Orders of Magnitude Improved Cyclotron-Mode Cooling for Non-Destructive Spin Quantum Transition Spectroscopy with Single Trapped Antiprotons
B. M. Latacz, M. Fleck, J. I. Jaeger +21
We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures below mK in p…
A 16 Parts per Trillion Comparison of the Antiproton-to-Proton q/m Ratios
M. J. Borchert, J. A. Devlin, S. E. Erlewein +20
The Standard Model (SM) of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter…
Image-current mediated sympathetic laser cooling of a single proton in a Penning trap down to 170 mK axial temperature
C. Will, M. Wiesinger, P. Micke +22
We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled Be. An axial mode temp…
Ultra thin polymer foil cryogenic window for antiproton deceleration and storage
B. M. Latacz, B. P. Arndt, J. A. Devlin +21
We present the design and characterisation of a cryogenic window based on an ultra-thin aluminised PET foil at T < 10K, which can withstand a pressure difference larger than 1bar a…
Trap-integrated fluorescence detection based on silicon photomultipliers in a cryogenic Penning trap
Markus Wiesinger, Florian Stuhlmann, Matthew A. Bohman +21
We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPM) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning…
BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies
C. Smorra, F. Abbass, M. Bohman +26
Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conduct…
Testing CPT Invariance by High-Precision Comparisons of Fundamental Properties of Protons and Antiprotons at BASE
E. J. Wursten, M. J. Borchert, J. A. Devlin +24
The BASE collaboration at the Antiproton Decelerator facility of CERN compares the fundamental properties of protons and antiprotons using advanced Penning-trap systems. In previou…
Sympathetic cooling schemes for separately trapped ions coupled via image currents
C. Will, M. Bohman, T. Driscoll +18
Cooling of particles to mK-temperatures is essential for a variety of experiments with trapped charged particles. However, many species of interest lack suitable electronic transit…
Sympathetic cooling of a trapped proton mediated by an LC circuit
M. Bohman, V. Grunhofer, C. Smorra +18
Efficient cooling of trapped charged particles is essential to many fundamental physics experiments, to high-precision metrology, and to quantum technology. Until now, sympathetic…
Millicharged dark matter detection with ion traps
Dmitry Budker, Peter W. Graham, Harikrishnan Ramani +3
We propose the use of trapped ions for detection of millicharged dark matter. Millicharged particles will scatter off the ions, giving a signal either in individual events or in th…
Constraints on the Coupling between Axionlike Dark Matter and Photons Using an Antiproton Superconducting Tuned Detection Circuit in a Cryogenic Penning Trap
Jack A. Devlin, Matthias J. Borchert, Stefan Erlewein +17
We constrain the coupling between axionlike particles (ALPs) and photons, measured with the superconducting resonant detection circuit of a cryogenic Penning trap. By searching the…
Direct limits on the interaction of antiprotons with axion-like dark matter
C. Smorra, Y. V. Stadnik, P. E. Blessing +18
Astrophysical observations indicate that there is roughly five times more dark matter in the Universe than ordinary baryonic matter, with an even larger amount of the Universe's en…
Precision measurements of the fundamental properties of the proton and antiproton
Christian Smorra, Andreas Mooser
Precision measurements comparing the fundamental properties of conjugate particles and antiparticles constitute stringent tests of CPT invariance. We review recent precision measur…
Measurement of ultra-low heating rates of a single antiproton in a cryogenic Penning trap
M. J. Borchert, P. E. Blessing, J. A. Devlin +15
We report on the first detailed study of motional heating in a cryogenic Penning trap using a single antiproton. Employing the continuous Stern-Gerlach effect we observe cyclotron…
Sympathetic Cooling of Protons and Antiprotons with a Common Endcap Penning Trap
M. Bohman, A. Mooser, G. Schneider +12
We present an experiment to sympathetically cool protons and antiprotons in a Penning trap by resonantly coupling the particles to laser cooled beryllium ions using a common endcap…
Observation of individual spin quantum transitions of a single antiproton
C. Smorra, A. Mooser, M. Besirli +15
We report on the detection of individual spin quantum transitions of a single trapped antiproton in a Penning trap. The spin-state determination, which is based on the unambiguous…
Highly-sensitive superconducting circuits at ~700 kHz with tunable quality factors for image-current detection of single trapped antiprotons
H. Nagahama, G. Schneider, A. Mooser +14
We developed highly-sensitive image-current detection systems based on superconducting toroidal coils and ultra-low noise amplifiers for non-destructive measurements of the axial f…
BASE - The Baryon Antibaryon Symmetry Experiment
C. Smorra, K. Blaum, L. Bojtar +17
The Baryon Antibaryon Symmetry Experiment (BASE) aims at performing a stringent test of the combined charge parity and time reversal (CPT) symmetry by comparing the magnetic moment…
A reservoir trap for antiprotons
Christian Smorra, Andreas Mooser, Kurt Franke +10
We have developed techniques to extract arbitrary fractions of antiprotons from an accumulated reservoir, and to inject them into a Penning-trap system for high-precision measureme…
Direct high-precision measurement of the magnetic moment of the proton
A. Mooser, S. Ulmer, K. Blaum +7
The spin-magnetic moment of the proton is a fundamental property of this particle. So far has only been measured indirectly, analysing the spectrum of an atomic hydroge…
The magnetic moments of the proton and the antiproton
S. Ulmer, A. Mooser, K. Blaum +14
Recent exciting progress in the preparation and manipulation of the motional quantum states of a single trapped proton enabled the first direct detection of the particle's spin sta…
Towards a high-precision measurement of the antiproton magnetic moment
C. Smorra, K. Blaum, K. Franke +10
The recent observation of single spins flips with a single proton in a Penning trap opens the way to measure the proton magnetic moment with high precision. Based on this success,…