output
19962026
most citedFormation of dense partonic matter in relativistic nucleus-nucleus collisions at RHIC: Experimental evaluation by the PHENIX collaboration

3k citations

Showing physics.ins-detShow all

64 papers · 1 filter

physics.ins-det2025

Study of neutron response using time of flight technique in ISMRAN detector

R. Dey, P. K. Netrakanti, D. K. Mishra +4

We report the measurements of the fast neutron energy response in Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) detector consisting of an array of 910 Plas…

physics.ins-det2025

Discrimination of neutron- in the low energy regime using machine learning for an EJ-276D plastic scintillator

S. Panda, P. K. Netrakanti, S. P. Behera +5

In this work, we present results for discrimination of neutron and events using a plastic scintillator detector with pulse shape discrimination capabilities. Machine learning (…

physics.ins-det2025★ 3 cited

Measurement of cosmic muon-induced neutron background with ISMRAN detector in a non-reactor environment

R. Dey, P. K. Netrakanti, D. K. Mishra +4

The Indian Scintillator Matrix for Reactor Anti-Neutrinos (ISMRAN) is an above-ground, very short baseline reactor anti-neutrino (${\overline{\ensuremathν}}_{e}$) experiment, locat…

physics.ins-det2023★ 5 cited

Calculation of true coincidence summing correction factor for a Broad Energy Germanium (BEGe) detector using standard and fabricated sources

Ashish Gupta, M. Shareef, Munmun Twisha +8

The true coincidence summing (TCS) correction factor for a Broad Energy Germanium (BEGe) detector has been calculated at far and close geometry measurement using multi-energetic ra…

physics.ins-det2022★ 5 cited

Evaluation of the response of plastic scintillator bars and measurement of neutron capture time in non-reactor environment for the ISMRAN experiment

R. Dey, P. K. Netrakanti, D. K. Mishra +4

We present a detailed study on detector response to different radioactive sources and the measurements of non-reactor environmental backgrounds with the Indian Scintillator Matrix…

physics.ins-det2022

Measurement of atmospheric muon angular distribution using a portable setup of liquid scintillator bars

Hariom Sogarwal, Prashant Shukla

Measurements of cosmogenic particles at various locations and altitudes are becoming increasingly important in view of worldwide interests in rare signals for search of new physics…

physics.ins-det2022★ 5 cited

A wide swing charge sensitive amplifier for a prototype Si-W EM calorimeter

Sourav Mukhopadhyay, Vinay B. Chandratre, Sanjib Muhuri +3

A wide swing charge sensitive amplifier (CSA) has been developed, as a part of a front-end electronics (FEE) readout ASIC, for a prototype silicon tungsten (Si-W) based electromagn…

physics.ins-det2021★ 5 cited

Characterization of plastic scintillator bars using fast neutrons from D-D and D-T reactions

R. Dey, P. K. Netrakanti, D. K. Mishra +6

We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Fa…

physics.ins-det2021★ 4 cited

Development and characterization of a large area silicon pad array for an electromagnetic calorimeter

Sourav Mukhopadhyay, Vinay B. Chandratre, Sanjib Muhuri +3

We present the research and development work of the first version of a 6*6 array of silicon pad detectors, carried out in India, for the proposed forward calorimeter (FOCAL) as par…

physics.ins-det2021★ 1 cited

Modeling the triple-GEM detector response to background particles for the CMS Experiment

M. Abbas, M. Abbrescia, H. Abdalla +186

An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the…

physics.ins-det2021★ 4 cited

An analytical model for electronic noise in a cryogenic bolometer detector readout circuit

V. Vatsa, A. Reza, A. Mazumdar +6

This paper presents an analytical model to quantify the measured noise in a cryogenic bolometer readout circuit. The model includes the contributions from the bias resistors and se…

physics.ins-det2020★ 33 cited

Imaging neutron capture cross sections: i-TED proof-of-concept and future prospects based on Machine-Learning techniques

V. Babiano-Suárez, J. Lerendegui-Marco, J. Balibrea-Correa +132

i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in () cross-section measurements using time-…

physics.ins-det2020★ 1 cited

Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade

M. Abbas, M. Abbrescia, H. Abdalla +178

We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensio…

physics.ins-det2020★ 30 cited

Reconstruction of signal amplitudes in the CMS electromagnetic calorimeter in the presence of overlapping proton-proton interactions

CMS Collaboration

A template fitting technique for reconstructing the amplitude of signals produced by the lead tungstate crystals of the CMS electromagnetic calorimeter is described. This novel app…

physics.ins-det2020★ 9 cited

A multi-stop time-of-flight spectrometer for the measurement of positron annihilation-induced electrons in coincidence with the Doppler-shifted annihilation gamma photon

V. A. Chirayath, R. W. Gladen, A. D. McDonald +12

Here we describe an advanced multi functional, variable-energy positron beam system capable of measuring the energies of multiple positron-induced electrons in coincidence with the…

physics.ins-det2019★ 64 cited

Performance of the reconstruction and identification of high-momentum muons in proton-proton collisions at 13 TeV

CMS Collaboration

The CMS detector at the LHC has recorded events from proton-proton collisions, with muon momenta reaching up to 1.8 TeV in the collected dimuon samples. These high-momentum muons a…

physics.ins-det2019

Review and new concepts for neutron-capture measurements of astrophysical interest

C. Domingo-Pardo, V. Babiano-Suarez, J. Balibrea-Correa +128

The idea of slow-neutron capture nucleosynthesis formulated in 1957 triggered a tremendous experimental effort in different laboratories worldwide to measure the relevant nuclear p…

physics.ins-det2019★ 10 cited

Fabrication and beam test of a silicon-tungsten electromagnetic calorimeter

Sanjib Muhuri, Sourav Mukhopadhyay, Vinay B. Chandratre +13

A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm) and tungsten absorbers (each of one rad…

physics.ins-det2019★ 8 cited

Calibration of the CMS hadron calorimeters using proton-proton collision data at 13 TeV

CMS Collaboration

Methods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass…

physics.ins-det2019★ 2 cited

RE3/1 and RE4/1 RPC chambers integration in the inner region of the forward muon spectrometer in the CMS experiment

E. Voevodina, I. Crotty

The high pseudorapidity () region of the Compact Muon Solenoid (CMS) muon system is covered by Cathode Strip Chambers only and lacks redundant coverage despite the fact that it…

physics.ins-det2019★ 12 cited

Performance of prototype GE1/1 chambers for the CMS muon spectrometer upgrade

CMS Muon Group

The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order…

physics.ins-det2019★ 3 cited

Interpretation of coincidence data from strip detectors and extraction of absolute cross section using 3-body Monte Carlo simulation method

S. K. Pandit, K. Mahata, A. Shrivastava +2

Accurate knowledge of the response of the detection system is very crucial for unambiguous interpretation of the experimental data. A simulation code has been developed using the M…

physics.ins-det2018★ 23 cited

Layout and Assembly Technique of the GEM Chambers for the Upgrade of the CMS First Muon Endcap Station

Aashaq Shah, CMS-Muon Collaboration

Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high ra…

physics.ins-det2018★ 16 cited

The CMS RPC Detector Performance and Stability during LHC RUN-2

M. A. Shah, R. Hadjiska

The CMS experiment, located at the Large Hadron Collider (LHC) in CERN, has a redundant muon system composed by three different gaseous detector technologies: Cathode Strip Chamber…