most citedExtension of the Cosmic-Ray Energy Spectrum Beyond the Predicted Greisen-Zatsepin-Kuz'min Cutoff

674 citations

Showing physics.med-phShow all

10 papers · 1 filter

physics.med-ph2018★ 2 cited

Technical Note: Reconstruction of physical and biological dose distributions of carbon-ion beam through deconvolution of longitudinal dosimeter responses

Nobuyuki Kanematsu, Taku Inaniwa, Shunsuke Yonai +1

Purpose: This is a theoretical simulation study for proof of concept of radiochromic film dosimetry to measure physical and biological doses without plan-based quenching correction…

physics.med-ph2017★ 15 cited

Estimation of linear energy transfer distribution for broad-beam carbon-ion radiotherapy at the National Institute of Radiological Sciences, Japan

Nobuyuki Kanematsu, Naruhiro Matsufuji, Taku Inaniwa

Carbon-ion radiotherapy (CIRT) is generally evaluated with the dose weighted by relative biological effectiveness (RBE), while the radiation quality varying in the body of each pat…

physics.med-ph2016★ 7 cited

Biological dose representation for carbon-ion radiotherapy of unconventional fractionation

Nobuyuki Kanematsu, Taku Inaniwa

In carbon-ion radiotherapy, single-beam delivery each day in alternate directions has been commonly practiced for operational efficiency, taking advantage of the Bragg peak and the…

physics.med-ph2015★ 45 cited

Relationship between mass density, electron density, and elemental composition of body tissues for Monte Carlo simulation in radiation treatment planning

Nobuyuki Kanematsu

Purpose: For Monte Carlo simulation of radiotherapy, x-ray CT number of every system needs to be calibrated and converted to mass density and elemental composition. This study aims…

physics.med-ph2013★ 3 cited

Influence of nuclear interactions in polyethylene range compensators for carbon-ion radiotherapy

Nobuyuki Kanematsu, Yusuke Koba, Risa Ogata +1

\item[Purpose] A recent study revealed that polyethylene (PE) would cause extra carbon-ion attenuation per range shift by 0.45\%/cm due to compositional differences in nuclear inte…

physics.med-ph2012★ 17 cited

Evaluation of plastic materials for range shifting, range compensation, and solid-phantom dosimetry in carbon-ion radiotherapy

Nobuyuki Kanematsu, Yusuke Koba, Risa Ogata

Purpose: Beam range control is the essence of radiotherapy with heavy charged particles. In conventional broad-beam delivery, fine range adjustment is achieved by insertion of rang…

physics.med-ph2010★ 5 cited

Modeling of beam customization devices in the pencil beam splitting algorithm for heavy charged particle radiotherapy

Nobuyuki Kanematsu

A broad-beam-delivery system for heavy-charged-particle radiotherapy often employs multiple collimators and a range-compensating filter, which potentially offer complex beam custom…

physics.med-ph2009★ 28 cited

Dose calculation algorithm of fast fine-heterogeneity correction for heavy charged particle radiotherapy

Nobuyuki Kanematsu

This work addresses computing techniques for dose calculations in treatment planning with proton and ion beams, based on an efficient kernel-convolution method referred to as grid-…

physics.med-ph2007★ 21 cited

The grid-dose-spreading algorithm for dose distribution calculation in heavy charged particle radiotherapy

Nobuyuki Kanematsu, Shunsuke Yonai, Azusa Ishizaki

A new variant of the pencil-beam (PB) algorithm for dose distribution calculation for radiotherapy with protons and heavier ions, the grid-dose spreading (GDS) algorithm, is propos…

physics.med-ph2007★ 29 cited

Emulsion Cloud Chamber technique to measure the fragmentation of a high-energy carbon beam

G. De Lellis, S. Buontempo, F. Di Capua +13

Beams of Carbon nuclei are used or planned to be used in various centers for cancer treatment around the world because of their therapeutic advantages over proton beams. The knowle…