output
20062026
most citedScience with the Einstein Telescope: a comparison of different designs

402 citations

Showing physics.ins-detShow all

25 papers · 1 filter

physics.ins-det2026★ 1 cited

Simulation and optimization of the Active Magnetic Shield of the n2EDM experiment

N. J. Ayres, G. Ban, G. Bison +47

The n2EDM experiment at the Paul Scherrer Institute aims to conduct a high-sensitivity search for the electric dipole moment of the neutron. Magnetic stability and control are achi…

physics.ins-det2025

Electromagnetic energy calibration of the SoLid detector with horizontal muons

SoLid collaboration

SoLid is a neutrino experiment at very-short baseline searching for active-to-sterile oscillations of reactor antineutrinos. The detection principle is based on the pairing of two…

physics.ins-det2024★ 2 cited

The CCube reconstruction algorithm for the SoLid experiment

The SoLid collaboration

The SoLid experiment is a very-short-baseline experiment aimed at searching for nuclear reactor-produced active to sterile antineutrino oscillations. The detection principle is bas…

physics.ins-det2023★ 10 cited

Characterization of a gas detector prototype based on Thick-GEM for the MAGNEX focal plane detector

I. Ciraldo, G. A. Brischetto, D. Torresi +18

A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN pro…

physics.ins-det2023★ 11 cited

STRASSE: A Silicon Tracker for Quasi-free Scattering Measurements at the RIBF

H. N. Liu, F. Flavigny, H. Baba +35

STRASSE (Silicon Tracker for RAdioactive nuclei Studies at SAMURAI Experiments) is a new detection system under construction for quasi-free scattering (QFS) measurements at 200-250…

physics.ins-det2022★ 39 cited

The `n2EDM MSR' -- a very large magnetically shielded room with an exceptional performance for fundamental physics measurements

N. J. Ayres, G. Ban, G. Bison +41

We present the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute which features an interior cubic volume with each side of length 2.92m, thus…

physics.ins-det2021★ 3 cited

OuroborosBEM: A fast multi-GPU microscopic Monte Carlo simulation for gaseous detectors and charged particle dynamics

G. Quéméner, S. Salvador

The design of gaseous detectors for accelerator, particle and nuclear physics requires simulations relying on multi-physics aspects. In fact, these simulations deal with the dynami…

physics.ins-det2021★ 24 cited

The MUGAST-AGATA-VAMOS campaign : set-up and performance

M. Assié, E. Clément, A. Lemasson +46

The MUGAST-AGATA-VAMOS set-up at GANIL combines the MUGAST highly-segmented silicon array with the state-of-the-art AGATA array and the large acceptance VAMOS spectrometer. The mec…

physics.ins-det2021★ 12 cited

Development of an energy-sensitive detector for the Atom Probe Tomography

Christian Bacchi, Gérald Da Costa, Emmanuel Cadel +5

A position-energy-sensitive detector has been developed for APT instruments in order to deal with some mass peak overlap issues encountered in APT experiments. Through this new typ…

physics.ins-det2021★ 53 cited

The design of the n2EDM experiment

N. J. Ayres, G. Ban, L. Bienstman +58

We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carr…

physics.ins-det2020

Geant4 Systematic Study of the FRACAS Apparatus for Hadrontherapy Cross Section Measurements

Edgar Barlerin, Samuel Salvador, Marc Labalme

In this work, we report on systematic Monte Carlo (MC) studies for the FRACAS apparatus, a large acceptance mass spectrometer that will be used to measure the fragmentation cross s…

physics.ins-det2020★ 37 cited

Neutron- discrimination with organic scintillators: Intrinsic pulse shape and light yield contributions

M. Sénoville, F. Delaunay, M. Pârlog +2

A comparative study of the neutron- Pulse Shape Discrimination (PSD) with seven organic scintillators is performed using an identical setup and digital electronics. The scintill…

physics.ins-det2020★ 3 cited

Geometry optimisation of a transparent axisymmetric ion trap for the MORA project

M. Benali, G. Quéméner, P. Delahaye +3

In the frame of the project MORA (Matter's Origin from the Radio Activity of trapped and oriented ions), a transparent axially symmetric radio-frequency ion trap (MORATrap) was des…

physics.ins-det2019★ 6 cited

Boron-10 conversion layer for ultra-cold neutron detection

Benoit Clement, Alexandre Bes, Ana Lacoste +5

We report on the development of a 10B conversion layer optimized for ultra-cold neutron detection with silicon detectors. The efficiency of this layer is high and roughly uniform o…

physics.ins-det2018★ 6 cited

Development of a Quality Assurance Process for the SoLid Experiment

Y. Abreu, Y. Amhis, G. Ban +53

The SoLid experiment has been designed to search for an oscillation pattern induced by a light sterile neutrino state, utilising the BR2 reactor of SCKCEN, in Belgium. The…

physics.ins-det2018★ 8 cited

Commissioning and Operation of the Readout System for the SoLid Neutrino Detector

Y. Abreu, Y. Amhis, G. Ban +53

The SoLid experiment aims to measure neutrino oscillation at a baseline of 6.4 m from the BR2 nuclear reactor in Belgium. Anti-neutrinos interact via inverse beta decay (IBD), resu…

physics.ins-det2018★ 17 cited

The MORA project

P. Delahaye, E. Liénard, I. Moore +25

The MORA (Matter's Origin from the RadioActivity of trapped and oriented ions) project aims at measuring with unprecedented precision the D correlation in the nuclear beta decay of…

physics.ins-det2018★ 14 cited

nEDM experiment at PSI: data-taking strategy and sensitivity of the dataset

C. Abel, N. J. Ayres, G. Ban +40

We report on the strategy used to optimize the sensitivity of our search for a neutron electric dipole moment at the Paul Scherrer Institute. Measurements were made upon ultracold…

physics.ins-det2018★ 35 cited

Magnetic field uniformity in neutron electric dipole moment experiments

C. Abel, N. Ayres, T. Baker +53

Magnetic field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A general parametrization of the magnetic field in terms…

physics.ins-det2018★ 34 cited

The n2EDM experiment at the Paul Scherrer Institute

C. Abel, N. J. Ayres, G. Ban +45

We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum…

physics.ins-det2018★ 7 cited

The open LPC Paul trap for precision measurements in beta decay

P. Delahaye, G. Ban, M. Benali +14

The LPCTrap experiment uses an open Paul trap which was built to enable precision measurements in the beta decay of radioactive ions. The initial goal was the precise measurement o…

physics.ins-det2018★ 41 cited

The FAZIA setup: a review on the electronics and the mechanical mounting

S. Valdré, G. Casini, N. Le Neindre +78

In this paper the technological aspects of the FAZIA array will be explored. After a productive commissioning phase, FAZIA blocks started to measure and give very useful data to ex…

physics.ins-det2017★ 14 cited

Improving isotopic identification with \emph{INDRA} Silicon-CsI(\emph{Tl}) telescopes

O. Lopez, M. Parlog, B. Borderie +21

Profiting from previous works done with the \emph{INDRA} multidetector on the description of the light response of the CsI(\emph{Tl}) crystals to different impinging n…

physics.ins-det2017★ 27 cited

The BiPo-3 detector for the measurement of ultra low natural radioactivities of thin materials

A. S. Barabash, A. Basharina-Freshville, E. Birdsall +93

The BiPo-3 detector, running in the Canfranc Underground Laboratory (Laboratorio Subterráneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measu…