161 citations
Counting papers with at most 25 authors, so collaboration author lists do not stand in for the people here.
- Istituto Nazionale di Fisica Nucleare, Sezione di TorinoIT8 papers
- Istituto Nazionale di Fisica Nucleare, Sezione di MilanoIT7 papers
- Istituto Nazionale di Fisica Nucleare, Sezione di PaviaIT5 papers
- Istituto Nazionale di Fisica Nucleare, Sezione di BolognaIT4 papers
- Istituto Nazionale di Fisica Nucleare, Sezione di NapoliIT4 papers
- Istituto Nazionale di Fisica Nucleare, Sezione di PisaIT4 papers
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma IIT4 papers
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma TreIT4 papers
- University of BolognaIT4 papers
- University of PaviaIT4 papers
- University of PisaIT4 papers
- University of TurinIT4 papers
6 papers · 1 filter
Stopping power monitoring during proton therapy by means of prompt gamma timing: first experimental results with a homogeneous phantom
Julius Werner, Francesco Pennazio, Piergiorgio Cerello +11
Proton therapy's full potential is limited by uncertainties that prevent optimal dose distribution. Monitoring techniques can reduce these uncertainties and enable adaptive treatme…
Analysis methods for in-beam PET images in proton therapy treatment verification: a comparison based on Monte Carlo simulations
M. Moglioni, A. C. Kraan, A. Berti +13
Background and purpose: In-beam Positron Emission Tomography (PET) is one of the modalities that can be used for in-vivo non-invasive treatment monitoring in proton therapy. PET di…
Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy
Alfredo Mirandola, S. Molinelli, G. Vilches Freixas +9
Purpose: To describe the dosimetric commissioning and quality assurance (QA) of the actively scanned proton and carbon ion beams at the Italian National Center for Oncological Hadr…
The CNAO Dose Delivery System for modulated scanning ion beam radiotherapy
Simona Giordanengo, Maria Adelaide Garella, Flavio Marchetto +9
This paper describes the dose delivery system used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. CNAO Foundation, INFN and…
A new detector for the beam energy measurement in proton therapy: a feasibility study
A. Vignati, S. Giordanengo, F. Mas Milian +14
Fast procedures for the beam quality assessment and for the monitoring of beam energy modulations during the irradiation are among the most urgent improvements in particle therapy.…
First tests for an online treatment monitoring system with in-beam PET for proton therapy
Aafke C. Kraan, G. Battistoni, N. Belcari +13
PET imaging is a non-invasive technique for particle range verification in proton therapy. It is based on measuring the beta+ annihilations caused by nuclear interactions of the pr…