output
19952026
most citedGW170817: Observation of Gravitational Waves from a Binary Neutron Star Inspiral

9.8k citations

Showing 2020 · physics.ins-detShow all

22 papers · 2 filters

physics.ins-det2020★ 6 cited

Search for double -decay modes of Zn using purified zinc

F. Bellini, M. Beretta, L. Cardani +27

The production of ultra-pure raw material is a crucial step to ensure the required background level in rare event searches. In this work, we establish an innovative technique devel…

physics.ins-det2020★ 24 cited

Novel technique for the study of pile-up events in cryogenic bolometers

A. Armatol, E. Armengaud, W. Armstrong +166

Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such…

physics.ins-det2020★ 91 cited

Calibration Strategy of the JUNO Experiment

JUNO collaboration, Angel Abusleme, Thomas Adam +588

We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multi…

physics.ins-det2020★ 10 cited

Single photon time resolution of photodetectors at high rate: Hamamatsu R13742 MaPMT and R10754 MCP-PMT

M. Calvi, S. Capelli, P. Carniti +2

This paper reports on the time resolution of two photodetectors operated as single photon counters at high rate: a Hamamatsu R13742-103-M64 "conventional" (based on metal dynodes)…

physics.ins-det2020★ 20 cited

Characterization of Silicon Drift Detectors with Electrons for the TRISTAN Project

S. Mertens, T. Brunst, M. Korzeczek +30

Sterile neutrinos are a minimal extension of the Standard Model of Particle Physics. A promising model-independent way to search for sterile neutrinos is via high-precision beta sp…

physics.ins-det2020★ 7 cited

An automated system to define the optimal operating settings of cryogenic calorimeters

Krystal Alfonso, Carlo Bucci, Lucia Canonica +7

Cryogenic macro-calorimeters instrumented with NTD thermistors have been developed for several decades. The choice of the optimal bias current is crucial for a proper operation of…

physics.ins-det2020★ 123 cited

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

DUNE Collaboration, B. Abi, A. Abed Abud +987

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of m. It is installed at the CERN Neutrino Plat…

physics.ins-det2020★ 36 cited

Characterization of a Silicon Drift Detector for High-Resolution Electron Spectroscopy

Matteo Gugiatti, Matteo Biassoni, Marco Carminati +8

Silicon Drift Detectors, widely employed in high-resolution and high-rate X-ray applications, are considered here with interest also for electron detection. The accurate measuremen…

physics.ins-det2020★ 11 cited

The ENUBET positron tagger prototype: construction and testbeam performance

F. Acerbi, M. Bonesini, F. Bramati +50

A prototype for the instrumented decay tunnel of ENUBET was tested in 2018 at the CERN East Area facility with charged particles up to 5 GeV. This detector is a longitudinal sampli…

physics.ins-det2020★ 45 cited

Neutrino interaction classification with a convolutional neural network in the DUNE far detector

DUNE Collaboration, B. Abi, R. Acciarri +968

The Deep Underground Neutrino Experiment is a next-generation neutrino oscillation experiment that aims to measure -violation in the neutrino sector as part of a wider physics…

physics.ins-det2020★ 30 cited

Reconstruction of signal amplitudes in the CMS electromagnetic calorimeter in the presence of overlapping proton-proton interactions

CMS Collaboration

A template fitting technique for reconstructing the amplitude of signals produced by the lead tungstate crystals of the CMS electromagnetic calorimeter is described. This novel app…

physics.ins-det2020★ 20 cited

Performance of the upgraded PreProcessor of the ATLAS Level-1 Calorimeter Trigger

ATLAS Collaboration

The PreProcessor of the ATLAS Level-1 Calorimeter Trigger prepares the analogue trigger signals sent from the ATLAS calorimeters by digitising, synchronising, and calibrating them…

physics.ins-det2020★ 9 cited

Hunting keV sterile neutrinos with KATRIN: building the first TRISTAN module

Thibaut Houdy, Antonio Alborini, Konrad Altenmüller +21

The KATRIN (Karlsruhe Tritium Neutrino) experiment investigates the energetic endpoint of the tritium beta-decay spectrum to determine the effective mass of the electron anti-neutr…

physics.ins-det2020

Decay tunnel instrumentation for the ENUBET neutrino beam

F. Acerbi, A. Berra, M. Bonesini +56

The uncertainty in the initial neutrino flux is the main limitation for a precise determination of the absolute neutrino cross section. The ERC funded ENUBET project (2016-2021) is…

physics.ins-det2020★ 322 cited

Performance of the ATLAS muon triggers in Run 2

ATLAS Collaboration

The performance of the ATLAS muon trigger system is evaluated with proton-proton () and heavy-ion (HI) collision data collected in Run 2 during 2015-2018 at the Large Hadron Co…

physics.ins-det2020★ 9 cited

The laser diode calibration system of the ICARUS T600 detector at FNAL

M. Bonesini, R. Benocci, R. Bertoni +6

The ICARUS T600 LAr TPC is the far detector of the Short Baseline Program at FNAL. As it will have to work at shallow depth in the Booster Neutrino Beam, a large cosmic rays backgr…

physics.ins-det2020★ 8 cited

Ce:LaBr crystals with SiPM array readout and temperature control for the FAMU experiment at RAL

M. Bonesini, R. Benocci, R. Bertoni +10

Compact X-rays detectors made of 1/2 inch Ce:LaBr3 crystals of cubic shape with SiPM array readout have been developed for the FAMUexperiment at RIKEN-RAL, to instrument regions of…

physics.ins-det2020★ 31 cited

Embedded Readout Electronics R&D for the Large PMTs in the JUNO Experiment

M. Bellato, A. Bergnoli, A. Brugnera +91

Jiangmen Underground neutrino Observatory (JUNO) is a next generation liquid scintillator neutrino experiment under construction phase in South China. Thanks to the anti-neutrinos…

physics.ins-det2020★ 16 cited

Cryogenic SiPM arrays for the DUNE photon detection system

A. Falcone, A. Andreani, S. Bertolucci +29

In this paper we report on the characterization of SiPM tiles developed for the R & D on the DUNE Photon Detection System. The tiles were produced by Fondazione Bruno Kessler (FBK)…

physics.ins-det2020★ 17 cited

Polysiloxane-based scintillators for shashlik calorimeters

F. Acerbi, A. Branca, C. Brizzolari +46

We present the first application of polysiloxane-based scintillators as active medium in a shashlik sampling calorimeter. These results were obtained from a testbeam campaign of a…

physics.ins-det2020★ 6 cited

Study of space charge in the ICARUS T600 detector

M. Antonello, B. Baibussinov, V. Bellini +45

The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field af…

physics.ins-det2020★ 9 cited

Experimental Study of Different Silicon Sensor Options for the Upgrade of the CMS Outer Tracker

The Tracker Group of the CMS Collaboration

During the high-luminosity phase of the LHC (HL-LHC), planned to start around 2027, the accelerator is expected to deliver an instantaneous peak luminosity of up to $7.5\times10^{3…