output
19952026
most citedGW170817: Observation of Gravitational Waves from a Binary Neutron Star Inspiral

9.8k citations

Showing 2018 · physics.ins-detShow all

16 papers · 2 filters

physics.ins-det2018★ 1 cited

NIEL DOSE and DLTS Analyses on Triple and Single Junction solar cells irradiated with electrons and protons

Roberta Campesato, Carsten Baur, Mariacristina Casale +7

Space solar cell radiation hardness is of fundamental importance in view of the future missions towards harsh radiation environment (like the Jupiter missions) and for the new spac…

physics.ins-det2018★ 24 cited

Status of the HOLMES Experiment to Directly Measure the Neutrino Mass

A. Nucciotti, B. Alpert, M. Balata +35

The assessment of neutrino absolute mass scale is still a crucial challenge in today particle physics and cosmology. Beta or electron capture spectrum end-point study is currently…

physics.ins-det2018★ 39 cited

A data acquisition and control system for large mass bolometer arrays

S. Di Domizio, A. Branca, A. Caminata +7

During the last couple of decades, the use of arrays of bolometers has represented one of the leading techniques for the search for rare events. CUORE, an array of 988 TeO bolo…

physics.ins-det2018★ 26 cited

Test and characterization of 400 Hamamatsu R5912-MOD photomultiplier tubes for the ICARUS T600 detector

M. Babicz, L. Bagby, B. Baibussinov +35

ICARUS T600 will be operated as far detector of the Short Baseline Neutrino program at Fermilab (USA), which foresees three liquid argon time projection chambers along the Booster…

physics.ins-det2018

An innovative technique for TPB deposition on convex window photomultiplier tubes

M. Bonesini, T. Cervi, A. Falcone +13

Tetraphenyl-butadiene (TPB) is an organic fluorescent chemical compound generally used as wavelength shifter thanks to its extremely high efficiency to convert ultra-violet photons…

physics.ins-det2018★ 20 cited

Precision measurement of the structure of the CMS inner tracking system using nuclear interactions

CMS Collaboration

The structure of the CMS inner tracking system has been studied using nuclear interactions of hadrons striking its material. Data from proton-proton collisions at a center-of-mass…

physics.ins-det2018★ 40 cited

Analysis of cryogenic calorimeters with light and heat read-out for double beta decay searches

O. Azzolini, M. T. Barrera, J. W. Beeman +47

The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors b…

physics.ins-det2018★ 10 cited

New read-out electronics for ICARUS-T600 liquid Argon TPC. Description, simulation and tests of the new front-end and ADC system

L. Bagby, B. Baibussinov, V. Bellini +42

The ICARUS T600, a liquid argon time projection chamber (LAr-TPC) detector mainly devoted to neutrino physics, underwent a major overhauling at CERN in 2016-2017, which included al…

physics.ins-det2018★ 33 cited

Single photon detection with SiPMs irradiated up to 10 cm 1-MeV-equivalent neutron fluence

M. Calvi, P. Carniti, C. Gotti +2

Silicon photomultipliers (SiPM) are solid state light detectors with sensitivity to single photons. Their use in high energy physics experiments, and in particular in ring imaging…

physics.ins-det2018★ 12 cited

The CUORE cryostat

A. D'Addabbo, M. Biassoni, C. Bucci +38

The Cryogenic Underground Observatory for Rare Events (CUORE) is a bolometric experiment for neutrinoless double-beta decay in Te search, currently taking data at the under…

physics.ins-det2018★ 528 cited

Performance of the CMS muon detector and muon reconstruction with proton-proton collisions at 13 TeV

CMS Collaboration

The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013-2014 in preparation for running at higher LHC collision ene…

physics.ins-det2018★ 39 cited

Strong reduction of the effective radiation length in an axially oriented scintillator crystal

L. Bandiera, V. V. Tikhomirov, M. Romagnoni +14

We measured a considerable increase of the emitted radiation by 120 GeV/c electrons in an axially oriented lead tungstate scintillator crystal, if compared to the case in which the…

physics.ins-det2018★ 58 cited

Measurement of the neutron flux at spallation sources using multi-foil activation

Davide Chiesa, Massimiliano Nastasi, Carlo Cazzaniga +5

Activation analysis is used in this work to measure the flux of a fast neutron beamline at a spallation source over a wide energy spectrum, extending from thermal to hundreds of Me…

physics.ins-det2018★ 72 cited

CUPID-0: the first array of enriched scintillating bolometers for 0νββdecay investigations

O. Azzolini, M. T. Barrera, J. W. Beeman +47

The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of $^{82…

physics.ins-det2018★ 6 cited

Charge reconstruction in large-area photomultipliers

M. Grassi, M. Montuschi, M. Baldoncini +60

Large-area PhotoMultiplier Tubes (PMT) allow to efficiently instrument Liquid Scintillator (LS) neutrino detectors, where large target masses are pivotal to compensate for neutrino…

physics.ins-det2018★ 16 cited

Testbeam performance of a shashlik calorimeter with fine-grained longitudinal segmentation

G. Ballerini, A. Berra, R. Boanta +34

An iron- plastic-scintillator shashlik calorimeter with a 4.3 longitudinal segmentation was tested in November 2016 at the CERN East Area facility with charged particles up t…