output
20022011
most citedA constrained, total-variation minimization algorithm for low-intensity X-ray CT

102 citations

11 papers

physics.med-ph2011★ 2 cited

High resolution image reconstruction with constrained, total-variation minimization

Emil Y. Sidky, Rick Chartrand, Yuval Duchin +2

This work is concerned with applying iterative image reconstruction, based on constrained total-variation minimization, to low-intensity X-ray CT systems that have a high sampling…

physics.med-ph2010★ 102 cited

A constrained, total-variation minimization algorithm for low-intensity X-ray CT

Emil Y. Sidky, Yuval Duchin, Christer Ullberg +1

Purpose: We develop an iterative image-reconstruction algorithm for application to low-intensity computed tomography (CT) projection data, which is based on constrained, total-vari…

physics.ins-det2006★ 33 cited

A Novel UV Photon Detector with Resistive Electrodes

J. M. Bidault, P. Fonte, T. Francke +3

In this study we present first results from a new detector of UV photons: a thick gaseous electron multiplier (GEM) with resistive electrodes, combined with CsI or CsTe/CsI photoca…

physics.ins-det2005★ 15 cited

Novel Single Photon Detectors for UV Imaging

P. Fonte, T. Francke, N. Pavlopoulos +2

There are several applications which require high position resolution UV imaging. For these applications we have developed and successfully tested a new version of a 2D UV single p…

physics.ins-det2004★ 7 cited

A High Position Resolution X-ray Detector: an Edge on Illuminated Capillary Plate Combined with a Gas Amplification Structure

C. Iacobaeus, T. Francke, B. Lund-Jensen +4

We have developed and successfully tested a prototype of a new type of high position resolution hybrid X-ray detector. It contains a thin wall lead glass capillary plate converter…

physics.ins-det2004★ 8 cited

Micropattern Gaseous Detectors

T. Francke, V. Peskov

Currently a revolution is taking place in the development of gaseous detectors of photons and particles. Parallel plate-type and wire-type detectors which dominated for years in hi…

physics.ins-det2004★ 6 cited

Study of capillary-based gaseous detectors

C. Iacobaeus, T. Francke, M. Danielsson +2

We have studied gain vs. voltage characteristics and position resolutions of multistep capillary plates (two or three capillary plates operating in a cascade), as well as capillary…

physics.ins-det2004★ 20 cited

The development of gaseous detectors with solid photocathodes for low temperature

L. Periale, V. Peskov, C. Iacobaeus +5

There are several applications and fundamental research areas which require the detection of VUV light at cryogenic temperatures. For these applications we have developed and succe…

physics.ins-det2002★ 15 cited

Beyond the RICH: Innovative Photosensitive Gaseous Detectors for new Fields of Applications

P. Carlson, C. Iacobeaus, T. Francke +4

We have developed and successfully used several innovative designs of detectors with solid photocathodes. The main advantage of these detectors is that rather high gains (>10E4) ca…

physics.ins-det2002★ 12 cited

The Development and Study of High-Position Resolution (50 micron) RPCs for Imaging X-rays and UV photons

C. Iacobaeus, P. Fonte, T. Francke +4

Nowadays, commonly used Resistive Plate Chambers (RPCs) have counting rate capabilities of ~10E4Hz/cm2 and position resolutions of ~1cm. We have developed small prototypes of RPCs…

physics.ins-det2002★ 34 cited

Potential of RPCs for tracking

T. Francke, P. Fonte, V. Peskov +1

We have demonstrated that small gap (0.1 to 0.4 mm) RPCs made of low resistivity materials (less than 1E8 Ohm.cm) can operate at counting rates of up to 1E5 Hz/mm2 with position re…