22 citations · 85 across the 9 of their papers we have counts for
9 papers
A Study of the Operation of Especially Designed Photosensitive Gaseous Detectors at Cryogenic Temperatures
L. Periale, V. Peskov, C. Iacobaeus +4
In some experiments and applications there is need for large-area photosensitive detectors to operate at cryogenic temperatures. Nowadays, vacuum PMs are usually used for this purp…
Photosensitive Gaseous Detectors for Cryogenic Temperature Applications
L. Periale, V. Peskov, C. Iacobaeus +4
There are several proposals and projects today for building LXe Time Projection Chambers (TPCs) for dark matter search. An important element of these TPCs are the photomultipliers…
A High Position Resolution X-ray Detector: an Edge on Illuminated Capillary Plate Combined with a Gas Amplification Structure
C. Iacobaeus, T. Francke, B. Lund-Jensen +4
We have developed and successfully tested a prototype of a new type of high position resolution hybrid X-ray detector. It contains a thin wall lead glass capillary plate converter…
The Successful Operation of Hole-type Gaseous Detectors at Cryogenic Temperatures
L. Pereiale, V. Peskov, C. Iacobaeus +6
We have demonstrated that hole-type gaseous detectors, GEMs and capillary plates, can operate up to 77 K. For example, a single capillary plate can operate at gains of above 10E3 i…
Study of capillary-based gaseous detectors
C. Iacobaeus, T. Francke, M. Danielsson +2
We have studied gain vs. voltage characteristics and position resolutions of multistep capillary plates (two or three capillary plates operating in a cascade), as well as capillary…
The development of gaseous detectors with solid photocathodes for low temperature
L. Periale, V. Peskov, C. Iacobaeus +5
There are several applications and fundamental research areas which require the detection of VUV light at cryogenic temperatures. For these applications we have developed and succe…
The Development and Study of High-Position Resolution (50 micron) RPCs for Imaging X-rays and UV photons
C. Iacobaeus, P. Fonte, T. Francke +4
Nowadays, commonly used Resistive Plate Chambers (RPCs) have counting rate capabilities of ~10E4Hz/cm2 and position resolutions of ~1cm. We have developed small prototypes of RPCs…
Sporadic electron jets from cathodes - The main breakdown-triggering mechanism in gaseous detectors
C. Iacobaeus, M. Danielsson, P. Fonte +3
We have demonstrated experimentally that the main breakdown-triggering mechanism in most gaseous detectors, including micropattern gaseous detectors, is sporadic electron jets from…
Fundamentals of Gas Micropattern Detectors
V. Peskov, P. Fonte, M. Danielsson +3
We performed a new series of systematic studies of gain and rate characteristics of several micropattern gaseous detectors. Extending earlier studies, these measurements were done…