38 citations · 63 across the 8 of their papers we have counts for
8 papers
CBM T0 Detector Performance Study with Light Ions (4He, 12C) and the DOGMA Readout System
Yevhen Kozymka, Thomas Bergauer, Maximilian von Buelow +14
This paper presents the realization and performance of the CBM T0 detector system. Built upon an approximately 70 μm thin polycrystalline CVD (pcCVD) diamond sensor with pad metall…
Excitation Spectra of the Reaction near the -Meson Emission Threshold Measured in Coincidence with High-Momentum Protons
R. Sekiya, K. Itahashi, Y. K. Tanaka +74
The missing mass of the reaction has been measured near the -meson emission threshold in coincidence with a high-momentum proton to selectively collect $η…
Performance of newly constructed plastic scintillator barrel in the WASA-FRS experiments and evaluation of radiation damage effects on multi-pixel photon counter
Y. K. Tanaka, R. Sekiya, K. Itahashi +70
A barrel-shaped plastic scintillation counter with Multi-Pixel Photon Counter (MPPC) readout has been developed and operated in the first WASA-FRS experimental campaign at GSI. The…
A Custom Discrete Amplifier-Shaper-Discriminator Circuit for the Drift Chambers of the R3B Experiment at GSI
Michael Wiebusch, Henning Heggen, Michael Heil
This contribution presents a pragmatic approach to read-out electronics for drift chambers used in particle physics experiments, specifically for the R3B experiment at GSI. The des…
Twin GEM-TPC Prototype (HGB4) Beam Test at GSI and Jyväskylä - a Development for the Super-FRS at FAIR
F. García, R. Turpeinen, J. Äystö +18
The FAIR[1] facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI r…
Precision mass measurements of magnesium isotopes and implications on the validity of the Isobaric Mass Multiplet Equation
M. Brodeur, A. A. Kwiatkowski, O. M. Drozdowski +21
If the mass excess of neutron-deficient nuclei and their neutron-rich mirror partners are both known, it can be shown that deviations of the Isobaric Mass Multiplet Equation (IMME)…
Offline trapping of Fr in a magneto-optical trap from implantation of an Ac ion beam
M. Tandecki, J. Zhang, S. Aubin +10
We demonstrate a new technique to prepare an offline source of francium for trapping in a magneto-optical trap. Implanting a radioactive beam of Ac, da…
Breakdown of the Isobaric Multiplet Mass Equation for the A = 20 and 21 Multiplets
A. T. Gallant, M. Brodeur, C. Andreoiu +21
Using the Penning trap mass spectrometer TITAN, we performed the first direct mass measurements of 20,21Mg, isotopes that are the most proton-rich members of the A = 20 and A = 21…