activity
20022013
most citedAn Improved Limit on Invisible Decays of Positronium

152 citations · 409 across the 15 of their papers we have counts for

collaborators

15 papers

physics.ins-det2013★ 30 cited

ArDM: first results from underground commissioning

A. Badertscher, F. Bay, N. Bourgeois +26

The Argon Dark Matter experiment is a ton-scale double phase argon Time Projection Chamber designed for direct Dark Matter searches. It combines the detection of scintillation ligh…

physics.ins-det2013★ 8 cited

Status of the ArDM Experiment: First results from gaseous argon operation in deep underground environment

ArDM Collaboration, A. Badertscher, F. Bay +26

The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to…

physics.ins-det2012★ 1 cited

Performance of a 250L liquid Argon TPC for sub-GeV charged particle identification

PARC T32 collaboration, O. Araoka, A. Badertscher +38

We have constructed a liquid Argon TPC detector with fiducial mass of 150 kg as a part of the R&D program of the next generation neutrino and nucleon decay detector. This paper des…

physics.ins-det2010★ 44 cited

ArDM: a ton-scale LAr detector for direct Dark Matter searches

ArDM Collaboration, A. Marchionni, C. Amsler +41

The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to…

physics.ins-det2010★ 27 cited

First results on light readout from the 1-ton ArDM liquid argon detector for dark matter searches

C. Amsler, A. Badertscher, V. Boccone +38

ArDM-1t is the prototype for a next generation WIMP detector measuring both the scintillation light and the ionization charge from nuclear recoils in a 1-ton liquid argon target. T…

physics.ins-det2010★ 9 cited

Feasibility of high-voltage systems for a very long drift in liquid argon TPCs

S. Horikawa, A. Badertscher, L. Kaufmann +5

Designs of high-voltage (HV) systems for creating a drift electric field in liquid argon TPCs are reviewed. In ongoing experiments systems capable of approx. 100 kV are realised fo…

physics.ins-det2010★ 1 cited

The ArDM experiment

ArDM Collaboration, C. Amsler, A. Badertscher +51

The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintil…

hep-ex2008★ 19 cited

Energy reconstruction of electromagnetic showers from decays with the ICARUS T600 Liquid Argon TPC

The ICARUS Collaboration, A. Ankowski

We discuss the ICARUS T600 detector capabilities in electromagnetic shower reconstruction through the analysis of a sample of 212 events, coming from the 2001 Pavia surface test ru…

hep-ex2006★ 152 cited

An Improved Limit on Invisible Decays of Positronium

A. Badertscher, P. Crivelli, W. Fetscher +6

The results of a new search for positronium decays into invisible final states are reported. Convincing detection of this decay mode would be a strong evid ence for new physics bey…

hep-ex2006★ 47 cited

Measurement of Through-Going Particle Momentum By Means Of Multiple Scattering With The ICARUS T600 TPC

ICARUS Collaboration, A. Ankowski

The ICARUS collaboration has demonstrated, following the operation of a 600 ton (T600) detector at shallow depth, that the technique based on liquid Argon TPCs is now mature. The s…

physics.acc-ph2005★ 22 cited

Development of a high-efficiency pulsed slow positron beam for measurements with orthopositronium in vacuum

N. Alberola, T. Anthonioz, A. Badertscher +8

We have developed a high-efficiency pulsed slow positron beam for experiments with orthopositronium in vacuum. The new pulsing scheme is based on a double-gap coaxial buncher power…

physics.ins-det2005★ 15 cited

First results from a Liquid Argon Time Projection Chamber in a Magnetic Field

A. Badertscher, M. Laffranchi, A. Meregaglia +2

A small liquid argon Time Projection Chamber (LAr TPC) was operated for the first time in a magnetic field of 0.55 Tesla. The imaging properties of the detector were not affected b…

physics.ins-det2004★ 16 cited

First operation of a liquid Argon TPC embedded in a magnetic field

A. Badertscher, M. Laffranchi, A. Meregaglia +1

We have operated for the first time a liquid Argon TPC immersed in a magnetic field up to 0.55 T. We show that the imaging properties of the detector are not affected by the presen…

hep-ex2004★ 1 cited

A new experiment to search for the invisible decay of the orthopositronium

A. Badertscher, P. Crivelli, W. Fetscher +4

We propose an experiment to search for invisible decays of orthopositronium (o-Ps) with a 90% confidence sensitivity in the branching ratio as low as . Evidence for this d…

hep-ex2002★ 17 cited

Search for an exotic three-body decay of orthopositronium

A. Badertscher, P. Crivelli, M. Felcini +7

We report on a direct search for a three-body decay of the orthopositronium into a photon and two penetrating particles, o-Ps -> gamma + X1 + X2. The existence of this decay could…