activity
20002023
most citedA clock network for geodesy and fundamental science

462 citations · 3.5k across the 35 of their papers we have counts for

collaborators
Showing physics.atom-phShow all

16 papers · 1 filter

physics.atom-ph2019★ 45 cited

A new experiment to test parity symmetry in cold chiral molecules using vibrational spectroscopy

A Cournol, M. Manceau, M. Pierens +21

We present a brief review of our progress towards measuring parity violation in heavy-metal chiral complexes using mid-infrared Ramsey interferometry. We discuss our progress addre…

physics.atom-ph2017★ 82 cited

First international comparison of fountain primary frequency standards via a long distance optical fiber link

J. Guéna, S. Weyers, M. Abgrall +25

We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-S…

physics.atom-ph2016★ 95 cited

Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock

Jérôme Lodewyck, Sławomir Bilicki, Eva Bookjans +10

Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude…

physics.atom-ph2016★ 77 cited

Comparing a mercury optical lattice clock with microwave and optical frequency standards

R Tyumenev, M Favier, S Bilicki +9

In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of . Comparing this characterized fre…

physics.atom-ph2015★ 462 cited

A clock network for geodesy and fundamental science

C. Lisdat, G. Grosche, N. Quintin +32

Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the fr…

physics.atom-ph2015★ 52 cited

Atomic fountains and optical clocks at SYRTE: status and perspectives

M. Abgrall, B. Chupin, L. De Sarlo +9

In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application t…

physics.atom-ph2013★ 245 cited

Experimenting an optical second with strontium lattice clocks

R. Le Targat, L. Lorini, Y. Le Coq +17

Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, rea…

physics.atom-ph2012

Mid-IR frequency measurement using an optical frequency comb and a long-distance remote frequency reference

Bruno Chanteau, Olivier Lopez, Wei Zhang +6

We have built a frequency chain which enables to measure the absolute frequency of a laser emitting in the 28-31 THz frequency range and stabilized onto a molecular absorption line…

physics.atom-ph2012★ 29 cited

Laser locking to the 199Hg clock transition with 5.4x10^(-15)/sqrt(tau) fractional frequency instability

J. J. McFerran, D. V. Magalhaes, C. Mandache +5

With Hg atoms confined in an optical lattice trap in the Lamb-Dicke regime, we obtain a spectral line at 265.6 nm in which the full-width at half-maximum is <15Hz. Here we lock an…

physics.atom-ph2012★ 88 cited

A neutral atom frequency reference in the deep UV with 10^(-15) range uncertainty

J. J. McFerran, L. Yi, S. Mejri +5

We present an assessment of the (6s^{2})1S0 -> (6s7s)3P0 clock transition frequency in 199Hg with an uncertainty reduction of nearly three orders of magnitude and demonstrate an at…

physics.atom-ph2010★ 37 cited

An Ultra-Stable Referenced Interrogation System in the Deep Ultraviolet for a Mercury Optical Lattice Clock

S. T. Dawkins, R. Chicireanu, M. Petersen +5

We have developed an ultra-stable source in the deep ultraviolet, suitable to fulfill the interrogation requirements of a future fully-operational lattice clock based on neutral me…

physics.atom-ph2009★ 181 cited

Ultra-low noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock

J. Millo, M. Abgrall, M. Lours +8

We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liqu…

physics.atom-ph2007★ 85 cited

Accuracy Evaluation of an Optical Lattice Clock with Bosonic Atoms

Xavier Baillard, Mathilde Fouché, Rodolphe Le Targat +6

We report the first accuracy evaluation of an optical lattice clock based on the 1S0 - 3P0 transition of an alkaline earth boson, namely 88Sr atoms. This transition has been enable…

physics.atom-ph2007★ 8 cited

Measurement of excited-state transitions in cold calcium atoms by direct femtosecond frequency-comb spectroscopy

J. E. Stalnaker, Y. Le Coq, T. M. Fortier +3

We apply direct frequency-comb spectroscopy, in combination with precision cw spectroscopy, to measure the transition frequency in cold calc…

physics.atom-ph2006★ 56 cited

Kilohertz-resolution spectroscopy of cold atoms with an optical frequency comb

T. M. Fortier, Y. Le Coq, J. E. Stalnaker +4

We have performed sub-Doppler spectroscopy on the narrow intercombination line of cold calcium atoms using the amplified output of a femtosecond laser frequency comb. Injection loc…

physics.atom-ph2000★ 5 cited

Multi frequency evaporative cooling to BEC in a high magnetic field

V. Boyer, S. Murdoch, Y. Le Coq +3

We demonstrate a way to circumvent the interruption of evaporative cooling observed at high bias field for Rb atoms trapped in the (F=2, m=+2) ground state. Our scheme uses…