activity
19982020
most citedUnderground operation of the ICARUS T600 LAr-TPC: first results

147 citations · 949 across the 30 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

17 papers · 1 filter

physics.ins-det2020★ 8 cited

Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC

B. Aimard, L. Aizawa, C. Alt +160

The m demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these de…

physics.ins-det2018★ 25 cited

A 4 tonne demonstrator for large-scale dual-phase liquid argon time projection chambers

B. Aimard, Ch. Alt, J. Asaadi +169

A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplifi…

physics.ins-det2016★ 50 cited

The ArDM Liquid Argon Time Projection Chamber at the Canfranc Underground Laboratory: a ton-scale detector for Dark Matter Searches

ArDM Collaboration, J. Calvo, C. Cantini +20

The Argon Dark Matter (ArDM) experiment consists of a liquid argon (LAr) time projection chamber (TPC) sensitive to nuclear recoils resulting from scattering of hypothetical Weakly…

physics.ins-det2015★ 10 cited

Status of ArDM-1t: First observations from operation with a full ton-scale liquid argon target

ArDM Collaboration, J. Calvo, C. Cantini +23

ArDM-1t is the first operating ton-scale liquid argon detector for direct search of Dark Matter particles. Developed at CERN as Recognized Experiment RE18, the experiment has been…

physics.ins-det2014★ 41 cited

LBNO-DEMO: Large-scale neutrino detector demonstrators for phased performance assessment in view of a long-baseline oscillation experiment

L. Agostino, B. Andrieu, R. Asfandiyarov +111

In June 2012, an Expression of Interest for a long-baseline experiment (LBNO) has been submitted to the CERN SPSC. LBNO considers three types of neutrino detector technologies: a d…

physics.ins-det2013★ 30 cited

ArDM: first results from underground commissioning

A. Badertscher, F. Bay, N. Bourgeois +26

The Argon Dark Matter experiment is a ton-scale double phase argon Time Projection Chamber designed for direct Dark Matter searches. It combines the detection of scintillation ligh…

physics.ins-det2007★ 39 cited

Development of innovative micropattern gaseous detectors with resistive electrodes and first results of their applications

A. Di Mauro, B. Lund-Jensen, P. Martinengo +8

The paper summarizes our latest progress in the development of newly introduced micro pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the de…

physics.ins-det2006★ 17 cited

A New GEM-like Imaging Detector with Electrodes Coated with Resistive Layers

A. Di Mauro, B. Lund-Jensen, P. Martinengro +6

We have developed and tested several prototypes of GEM-like detectors with electrodes coated with resistive layers: CuO or CrO. These detectors can operate stably at gains close to…

physics.ins-det2006★ 52 cited

Performance Of A Liquid Argon Time Projection Chamber Exposed To The WANF Neutrino Beam

F. Arneodo et al.

We present the results of the first exposure of a Liquid Argon TPC to a multi-GeV neutrino beam. The data have been collected with a 50 liters ICARUS-like chamber located between t…

physics.ins-det2006★ 10 cited

The Development of Sealed UV Sensitive Gaseous Detectors and their Applications

L. Periale, V. Peskov, A. Braem +5

We have developed commercial prototypes of sealed gaseous detectors combined with CsI photocathodes and/or filled with photosensitive vapors. The rirst results of application of th…

physics.ins-det2005★ 22 cited

A Study of the Operation of Especially Designed Photosensitive Gaseous Detectors at Cryogenic Temperatures

L. Periale, V. Peskov, C. Iacobaeus +4

In some experiments and applications there is need for large-area photosensitive detectors to operate at cryogenic temperatures. Nowadays, vacuum PMs are usually used for this purp…

physics.ins-det2005★ 10 cited

Photosensitive Gaseous Detectors for Cryogenic Temperature Applications

L. Periale, V. Peskov, C. Iacobaeus +4

There are several proposals and projects today for building LXe Time Projection Chambers (TPCs) for dark matter search. An important element of these TPCs are the photomultipliers…

physics.ins-det2004★ 1 cited

The Successful Operation of Hole-type Gaseous Detectors at Cryogenic Temperatures

L. Pereiale, V. Peskov, C. Iacobaeus +6

We have demonstrated that hole-type gaseous detectors, GEMs and capillary plates, can operate up to 77 K. For example, a single capillary plate can operate at gains of above 10E3 i…

physics.ins-det2004★ 20 cited

The development of gaseous detectors with solid photocathodes for low temperature

L. Periale, V. Peskov, C. Iacobaeus +5

There are several applications and fundamental research areas which require the detection of VUV light at cryogenic temperatures. For these applications we have developed and succe…

physics.ins-det2002★ 15 cited

Beyond the RICH: Innovative Photosensitive Gaseous Detectors for new Fields of Applications

P. Carlson, C. Iacobeaus, T. Francke +4

We have developed and successfully used several innovative designs of detectors with solid photocathodes. The main advantage of these detectors is that rather high gains (>10E4) ca…

physics.ins-det2001★ 16 cited

Evaluation of various planar gaseous detectors with CsI photocathodes for the detection of primary scintillation light from noble gases

L. Periale, V. Peskov, P. Carlson +5

Noble gases and liquids are excellent scintillators and this opens a unique opportunity to directly detect the primary scintillation light produced in these media by photons or par…

physics.ins-det2001★ 128 cited

Detection of the primary scintillation light from dense Ar, Kr and Xe with novel photosensitive gaseous detectors

L. Periale, V. Peskov, P. Carlson +4

The detection of primary scintillation light in combination with the charge or secondary scintillation signals is an efficient technique to determine the events t=0 as well as part…