84 citations · 279 across the 27 of their papers we have counts for
8 papers · 1 filter
Radiative neutron capture cross section of Pu measured at n_TOF-EAR1 in the unresolved resonance region up to 600 keV
J. Lerendegui-Marco, C. Guerrero, E. Mendoza +133
Accurate neutron capture cross sections are essential for the design and operation of fast reactors using MOX fuels. For Pu, the Nuclear Energy Agency (NEA) recommends 8--1…
Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams
J. Balibrea-Correa, V. Babiano-Suarez, J. Lerendegui-Marco +134
Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn,…
A computer-vision aided Compton-imaging system for radioactive waste characterization and decommissioning of nuclear power plants
Victor Babiano-Suarez, Javier Balibrea-Correa, Ion Ladarescu +3
Nuclear energy production is inherently tied to the management and disposal of radioactive waste. Enhancing classification and monitoring tools is therefore crucial, with significa…
Towards Real Time Compton Imaging in Demanding Conditions
Bernardo Gameiro, Jorge Lerendegui-Marco, Victor Babiano-Suarez +5
Compton cameras are radiation detectors that provide spatial information on the origin of the γ-ray sources based on the Compton scattering effect. Many applications require these…
Imaging neutrons with a position-sensitive monolithic CLYC detector
J. Lerendegui-Marco, G. Cisterna, J. Hallam +9
In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and -ray Compton scatterer of the novel dual \g-ray a…
The i-TED Compton Camera Array for real-time boron imaging and determination during treatments in Boron Neutron Capture Therapy
Pablo Torres-Sánchez, Jorge Lerendegui-Marco, Javier Balibrea-Correa +12
This paper explores the adaptation and application of i-TED Compton imagers for real-time dosimetry in Boron Neutron Capture Therapy (BNCT). The i-TED array, previously utilized in…
First Pilot Tests of Compton Imaging and Boron Concentration Measurements in BNCT Using i-TED
J. Lerendegui-Marco, J. Balibrea-Correa, P. Álvarez-Rodríguez +10
Dosimetry in BNCT poses significant challenges due to the indirect effect of neutrons interacting with elements within the body and uncertainties associated with the uptake of boro…
A Segmented Total Energy Detector (sTED) optimized for cross-section measurements at n_TOF EAR2
V. Alcayne, D. Cano-Ott, J. Garcia +12
The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron-induced reaction cross-sections of interest in nuclear technologies, a…