38 citations · 152 across the 31 of their papers we have counts for
27 papers · 1 filter
Surface Commissioning and Performance of the sMDT Muon Chambers for the ATLAS HL-LHC Upgrade
Jiajin Ge, Elena Voevodina, Hubert Kroha +21
To improve the first-level muon trigger efficiency at the HL-LHC, the Monitored Drift Tube (MDT) chambers in the inner small sectors of the ATLAS Barrel Muon Spectrometer will be r…
Calibration of the discriminator threshold of the Amplifier-Shaper-Discriminator Chip for the Upgrade of the ATLAS Muon Drift-Tube Chambers for the High-Luminosity LHC
Oliver Kortner, Nick Meier, Julia Okfen
The read-out electronics of the ATLAS muon drift-tube chambers will be upgraded for operation at the High-Luminosity Large Hadron Collider. Part of the upgrade is the introduction…
The ASD2 Chip for the Upgrade of the ATLAS MDT Chamber Readout at HL-LHC
S. Abovyan, A. Baschirotto, V. Danielyan +8
Upgrading the ATLAS detector for operation at the High-Luminosity LHC requires a new, more se-lective trigger scheme to control the readout of MDT drift-tube chambers by incorporat…
Resistive Plate Chamber Detector Construction and Certification: State-of-the-Art Facilities at the Max Planck Institute for Physics, in Partnership with Industrial Partners
Davide Costa, Francesco Fallavollita, Hubert Kroha +6
Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred…
New Facilities for the Production of 1 mm gap Resistive Plate Chambers for the Upgrade of the ATLAS Muon Spectrometer
F. Fallavollita, O. Kortner, H. Kroha +5
The ATLAS Muon Spectrometer is undergoing a major upgrade for the High-Luminosity LHC (HL-LHC), including the addition of three new thin-gap Resistive Plate Chamber (RPC) layers in…
Commissioning and installation of the new small-Diameter Muon Drift Tube (sMDT) detectors for the Phase-I upgrade of the ATLAS Muon Spectrometer
G. H. Eberwein, O. Kortner, H. Kroha +5
The Monitored Drift Tubes, as a part of the ATLAS muon spectrometer, are precision drift chambers designed to provide excellent spatial resolution and high tracking efficiency inde…