activity
20132025
most citedThe Hot and Energetic Universe: The X-ray Integral Field Unit (X-IFU) for Athena+

43 citations · 470 across the 41 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

9 papers · 1 filter

physics.ins-det2021★ 1 cited

Demonstration of MHz frequency domain multiplexing readout of 37 transition edge sensors for high-resolution x-ray imaging spectrometers

H. Akamatsu, D. Vaccaro, L. Gottardi +22

We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalor…

physics.ins-det2021★ 7 cited

AC/DC characterization of a Ti/Au TES with Au/Bi absorber for X-ray detection

E. Taralli, C. Pobes, P. Khosropanah +7

Transition-edge sensors (TESs) are used as very sensitive thermometers in microcalorimeters aimed at detection of different wavelengths. In particular, for soft X-ray astrophysics,…

physics.ins-det2021★ 15 cited

Characterization of high aspect ratio TiAu TES X-ray microcalorimeters array using the X-IFU Frequency Domain Multiplexing readout

E. Taralli, L. Gottardi, K. Nagayoshi +7

We are developing X-ray microcalorimeters as a backup option for the baseline detectors in the X-IFU instrument on board the ATHENA space mission led by ESA and to be launched in t…

physics.ins-det2021★ 22 cited

Complex impedance of TESs under AC bias using FDM readout system

E. Taralli, P. Khosropanah, L. Gottardi +4

The next generation of Far-infrared and X-ray space observatories will require detector arrays with thousands of transition edge sensor (TES) pixel. It is extremely important to ha…

physics.ins-det2016★ 6 cited

AC bias characterization of low noise bolometers for SAFARI using an Open-Loop Frequency Domain SQUID-based multiplexer operating between 1 and 5 MHz

Luciano Gottardi, Marcel Bruijn, Jan-R. Gao +8

SRON is developing the Frequency Domain Multiplexing (FDM) readout and the ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on board of the Japanese space mi…

physics.ins-det2016★ 4 cited

Performance of an X-ray single pixel TES microcalorimeter under DC and AC biasing

Luciano Gottardi, Jan van der Kuur, Piet A. J. de Korte +7

We are developing Frequency Domain Multiplexing (FDM) for the read-out of TES imaging microcalorimeter arrays for future X-ray missions like IXO. In the FDMconfiguration the TES is…

physics.ins-det2016★ 10 cited

Characterisation of a TES-Based X-ray Microcalorimeter in the Energy Range from 150 to 1800 eV Using an Adiabatic Demagnetisation Refrigerator

Luciano Gottardi, Yoh Takei, Jan van der Kuur +8

We characterised a TES-based X-ray microcalorimeter in an adiabatic demagnetisation refrigerator (ADR) using synchrotron radiation. The detector response and energy resolution was…

physics.ins-det2016★ 32 cited

Josephson effects in an alternating current biased transition edge sensor

Luciano Gottardi, Alex Kozorezov, Hiroki Akamatsu +10

We report the experimental evidence of the ac Josephson effect in a transition edge sensor (TES) operating in a frequency domain multiplexer and biased by ac voltage at MHz frequen…

physics.ins-det2015★ 2 cited

Multiplexed readout demonstration of a TES-based detector array in a resistance locked loop

Jan van der Kuur, Luciano Gottardi, Mikko Kiviranta +5

TES-based bolometer and microcalorimeter arrays with thousands of pixels are under development for several space-based and ground-based applications. A linear detector response and…