activity
19972026
most citedCombined measurements of Higgs boson couplings in proton-proton collisions at 13 TeV

442 citations · 11.7k across the 439 of their papers we have counts for

collaborators
Showing 2022Show all

12 papers · 1 filter

hep-ex2022

Measurement of the cross section of top quark-antiquark pair production in association with a W boson in proton-proton collisions at TeV

Tu Thong Tran

The production of a top quark-antiquark pair in association with a W boson is measured in proton-proton collisions at a centre-of-mass energy of 13 TeV. The data recorded by the CM…

astro-ph.CO2022★ 43 cited

Results on sub-GeV Dark Matter from a 10 eV Threshold CRESST-III Silicon Detector

CRESST Collaboration, G. Angloher, S. Banik +59

We present limits on the spin-independent interaction cross section of dark matter particles with silicon nuclei, derived from data taken with a cryogenic calorimeter with 0.35 g t…

nucl-ex2022★ 8 cited

Measurements of azimuthal anisotropy of nonprompt D mesons in PbPb collisions at = 5.02 TeV

CMS Collaboration

Measurements of the elliptic () and triangular () azimuthal anisotropy coefficients are presented for D mesons produced in b hadron decays (nonprompt D mesons) in…

nucl-ex2022★ 20 cited

Observation of a nuclear recoil peak at the 100 eV scale induced by neutron capture

CRAB Collaboration, NUCLEUS Collaboration, H. Abele +75

Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observ…

physics.ins-det2022★ 13 cited

Towards an automated data cleaning with deep learning in CRESST

G. Angloher, S. Banik, D. Bartolot +62

The CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a caref…

hep-ex2022★ 16 cited

Proton reconstruction with the CMS-TOTEM Precision Proton Spectrometer

CMS, TOTEM Collaborations

The Precision Proton Spectrometer (PPS) of the CMS and TOTEM experiments collected 107.7 fb in proton-proton (pp) collisions at the LHC at 13 TeV (Run 2). This paper describ…

physics.ins-det2022★ 2 cited

Secular Equilibrium Assessment in a Target Crystal from the Dark Matter Experiment CRESST using Bayesian Likelihood Normalisation

G. Angloher, S. Banik, G. Benato +58

CRESST is a leading direct detection sub- dark matter experiment. During its second phase, cryogenic bolometers were used to detect nuclear recoils off the $\ma…

astro-ph.CO2022★ 39 cited

Testing spin-dependent dark matter interactions with lithium aluminate targets in CRESST-III

G. Angloher, S. Banik, G. Benato +58

In the past decades, numerous experiments have emerged to unveil the nature of dark matter, one of the most discussed open questions in modern particle physics. Among them, the CRE…

astro-ph.CO2022★ 24 cited

Latest observations on the low energy excess in CRESST-III

G. Angloher, S. Banik, G. Benato +57

The CRESST experiment observes an unexplained excess of events at low energies. In the current CRESST-III data-taking campaign we are operating detector modules with different desi…

physics.ins-det2022★ 6 cited

Cait: analysis toolkit for cryogenic particle detectors in Python

Felix Wagner, Daniel Bartolot, Damir Rizvanovic +3

Cryogenic solid state detectors are widely used in dark matter and neutrino experiments, and require a sensible raw data analysis. For this purpose, we present Cait, an open source…

astro-ph.IM2022★ 99 cited

EXCESS workshop: Descriptions of rising low-energy spectra

P. Adari, A. Aguilar-Arevalo, D. Amidei +303

Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the signifi…

physics.ins-det2022

Development of a compact muon veto for the NUCLEUS experiment

V. Wagner, R. Rogly, A. Erhart +52

The NUCLEUS experiment aims to measure coherent elastic neutrino nucleus scattering of reactor anti-neutrinos using cryogenic calorimeters. Operating at an overburden of 3 m.w.e.,…