7 citations · 16 across the 7 of their papers we have counts for
9 papers
Ionization Profile Monitors for the IOTA Storage Ring at Fermilab
R. Thurman-Keup, N. Banerjee, M. Bressler +8
Ionization profile monitors (IPM) are used in many accelerator laboratories around the world for non-destructive profile measurements of high-energy particle beams. They have been…
A Simulation of the Photoionization of H- Together with the Subsequent Tracking of the Liberated Electrons
R. Thurman-Keup, M. El Baz, V. Scarpine
The Proton Improvement Plan - II (PIP-II) is a new linear accelerator (LINAC) complex being built at Fermilab. It is based on superconducting radiofrequency cavities and will accel…
A Study of the Gain of Microchannel Plates in the Ionization Profile Monitors at Fermilab
R. Thurman-Keup, D. Slimmer, C. Lundberg +1
One of the on-going issues with the use of microchannel plates (MCP) in the ionization profile monitors (IPM) at Fermilab is the significant decrease in gain over time. There are s…
Progress on an Electron Beam Profile Monitor at the Fermilab Main Injector
R. Thurman-Keup, T. Folan, M. Mwaniki +1
The current program at Fermilab involves the construction of a new superconducting linear accelerator (LINAC) to replace the existing warm version. The new LINAC, together with oth…
Commissioning and first results of the Electron Beam Profiler in the Main Injector at Fermilab
R. Thurman-Keup, M. Alvarez, J. Fitzgerald +4
The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging an…
Installation status of the electron beam profiler for the Fermilab Main Injector
R. Thurman-Keup, M. Alvarez, J. Fitzgerald +5
The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging an…
Third generation residual gas ionization profile monitors at Fermilab
J. R. Zagel, M. Alvarez, B. Fellenz +6
The latest generation of IPMs installed in the Fermilab Main Injector and Recycler incorporate a 1 kG permanent magnet, a newly designed high-gain, rad-tolerant preamp, and a contr…
The upgraded data acquisition system for beam loss monitoring at the Fermilab Tevatron and Main Injector
A. Baumbaugh, C. Briegel, B. C. Brown +14
A VME-based data acquisition system for beam-loss monitors has been developed and is in use in the Tevatron and Main Injector accelerators at the Fermilab complex. The need for enh…
Synchrotron radiation based beam diagnostics at the Fermilab Tevatron
R. Thurman-Keup, H. W. K. Cheung, A. Hahn +7