activity
20112021
most citedUnexpected sawtooth artifact in beat-to-beat pulse transit time measured from patient monitor data

15 citations · 36 across the 10 of their papers we have counts for

collaborators

10 papers

q-bio.QM2021

Arterial blood pressure waveform in liver transplant surgery possesses variability of morphology reflecting recipients' acuity and predicting short term outcomes

Shen-Chih Wang, Chien-Kun Ting, Cheng-Yen Chen +5

Background: We investigated clinical information underneath the beat-to-beat fluctuation of the arterial blood pressure (ABP) waveform morphology. We proposed the Dynamical Diffusi…

eess.SP2020

Unsupervised Ensembling of Multiple Software Sensors with Phase Synchronization: A Robust Approach For Electrocardiogram-derived Respiration

Jacob McErlean, John Malik, Yu-Ting Lin +2

Objective: We aimed to fuse the outputs of different electrocardiogram-derived respiration (EDR) algorithms to create one EDR signal that is of higher quality. Methods: We viewed e…

q-bio.QM2019

Novel imaging revealing inner dynamics for cardiovascular waveform analysis via unsupervised manifold learning

Shen-Chih Wang, Hau-Tieng Wu, Po-Hsun Huang +3

Cardiovascular waveforms contain information for clinical diagnosis. By "learning" and organizing the subtle change of waveform morphology from large amounts of raw waveform data,…

stat.AP2019★ 3 cited

Wave-shape oscillatory model for nonstationary periodic time series analysis

Yu-Ting Lin, John Malik, Hau-Tieng Wu

The oscillations observed in many time series, particularly in biomedicine, exhibit morphological variations over time. These morphological variations are caused by intrinsic or ex…

q-bio.QM2019

Differentiation of skin incision and laparoscopic trocar insertion via quantifying transient bradycardia measured by electrocardiogram

Cheng-Hsi Chang, Yue-Lin Fang, Yu-Jung Wang +2

Background. Most surgical procedures involve structures deeper than the skin. However, the difference in surgical noxious stimulation between skin incision and laparoscopic trocar…

q-bio.QM2018★ 15 cited

Unexpected sawtooth artifact in beat-to-beat pulse transit time measured from patient monitor data

Yu-Ting Lin, Yu-Lun Lo, Chen-Yun Lin +2

Object: It is increasingly popular to collect as much data as possible in the hospital setting from clinical monitors for research purposes. However, in this setup the data calibra…

stat.AP2015★ 1 cited

When interpolation-induced reflection artifact meets time-frequency analysis

Yu-Ting Lin, Patrick Flandrin, Hau-tieng Wu

While extracting the temporal dynamical features based on the time-frequency analyses, like the reassignment and synchrosqueezing transform, attracts more and more interest in bio-…

q-bio.NC2015★ 8 cited

The Modeling and Quantification of Rhythmic to Non-rhythmic Phenomenon in Electrocardiography during Anesthesia

Yu-Ting Lin

Variations of instantaneous heart rate appears regularly oscillatory in deeper levels of anesthesia and less regular in lighter levels of anesthesia. It is impossible to observe th…

math.NA2014★ 5 cited

Real-time dynamics acquisition from irregular samples -- with application to anesthesia evaluation

Charles K. Chui, Yu-Ting Lin, Hau-tieng Wu

The first objective of this paper is to introduce a unified approach to the D/A conversion, a real-time algorithm referred to as {\it blending operator}, based on spline functions…

math.NA2011★ 4 cited

Using synchrosqueezing transform to discover breathing dynamics from ECG signals

Wu Hau-Tieng, Chan Yi-Hsin, Lin Yu-Ting +1

The acquisition of breathing dynamics without directly recording the respiratory signals is beneficial in many clinical settings. The electrocardiography (ECG)-derived respiration…