activity
19982026
most citedA Time-Of-Flight-Based Reconstruction for Real-Time Prompt-Gamma Imaging in Protontherapy

28 citations · 155 across the 14 of their papers we have counts for

collaborators

15 papers

physics.med-ph2026

Experimental Assessment of Prompt Gamma Time Imaging in Complex Anatomy

Pavel Kavrigin, Alicia Garnier, Adélie André +14

Prompt-gamma (PG) imaging is a promising approach for in vivo verification in proton therapy, but existing methods are primarily limited to reconstructing the PG emission profile,…

physics.med-ph2023★ 19 cited

A high sensitivity Cherenkov detector for Prompt Gamma Timing and Time Imaging

Maxime Jacquet, Saba Ansari, Marie-Laure Gallin-Martel +13

We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement alre…

physics.ins-det2021★ 9 cited

Performance of CVD diamond detectors for single ion beam-tagging applications in hadrontherapy monitoring

Sébastien Curtoni, Marie-Laure Gallin-Martel, Sara Marcatili +26

In the context of online ion range verification in particle therapy, the CLaRyS collaboration is developing Prompt-Gamma (PG) detection systems. The originality in the CLaRyS appro…

physics.med-ph2020★ 28 cited

A Time-Of-Flight-Based Reconstruction for Real-Time Prompt-Gamma Imaging in Protontherapy

Maxime Jacquet, Sara Marcatili, Marie-Laure Gallin-Martel +11

We are currently conceiving, through (MC) simulation, a multi-channel gamma detector array (TIARA for Time-of-flight Imaging ARrAy) for the online monitoring of protontherapy treat…

physics.med-ph2020★ 2 cited

A 100 ps TOF Detection System for On-Line Range- Monitoring in Hadrontherapy

Sara Marcatili, Sébastien Curtoni, Denis Dauvergne +11

The accuracy of hadrontherapy treatment is currently limited by ion-range uncertainties. In order to fully exploit the potential of this technique, we propose the development of a…

physics.med-ph2020★ 23 cited

Ultra-fast prompt gamma detection in single proton counting regime for range monitoring in particle therapy

S. Marcatili, J. Collot, S. Curtoni +12

In order to fully exploit the ballistic potential of particle therapy, we propose an online range monitoring concept based on high-resolution Time-Of-Flight (TOF)-resolved Prompt G…

physics.ins-det2019

Recent Results from Polycrystalline CVD Diamond Detectors

RD42 Collaboration, L. Bäni, A. Alexopoulos +109

Diamond is a material in use at many nuclear and high energy facilities due to its inherent radiation tolerance and ease of use. We have characterized detectors based on chemical v…

astro-ph.IM2012★ 25 cited

NIKEL: Electronics and data acquisition for kilopixels kinetic inductance camera

O. Bourrion, C. Vescovi, J. L. Bouly +5

A prototype of digital frequency multiplexing electronics allowing the real time monitoring of microwave kinetic inductance detector (MKIDs) arrays for mm-wave astronomy has been d…

physics.med-ph2008★ 10 cited

A liquid Xenon Positron Emission Tomograph for small animal imaging : first experimental results of a prototype cell

M. L. Gallin-Martel, L. Gallin-Martel, Y. Grondin +8

A detector using liquid Xenon (LXe) in the scintillation mode is studied for Positron Emission Tomography (PET) of small animals. Its specific design aims at taking full advantage…

astro-ph2006★ 5 cited

The Ring Imaging Cherenkov detector (RICH) of the AMS experiment

F. Barao, M. Aguilar Benitez, J. Alcaraz +37

The Alpha Magnetic Spectrometer (AMS) experiment to be installed on the International Space Station (ISS) will be equipped with a proximity focusing Ring Imaging Cherenkov (RICH) d…

physics.med-ph2005★ 11 cited

Experimental study of a liquid Xenon PET prototype module

M. -L. Gallin-Martel, P. Martin, F. Mayet +16

A detector using liquid Xenon in the scintillation mode is studied for Positron Emission Tomography (PET). The specific design aims at taking full advantage of the liquid Xenon pro…

physics.ins-det2005

Development of a TDC to equip a Liquid Xenon PET prototype

O. Bourrion, L. Gallin-Martel

A Time to Digital Converter was designed (CMOS 0.35 $\mum) in order to be used in Liquid Xenon PET prototype. The circuit proved to be able to work at -120 degrees C, while showing…

astro-ph2003★ 5 cited

The AMS-02 RICH Imager Prototype - In-Beam Tests with 20 GeV/c per Nucleon Ions -

M. Buenerd, P. Aguayo, M. Aguilar Benitez +32

A prototype of the AMS Cherenkov imager (RICH) has been tested at CERN by means of a low intensity 20 GeV/c per nucleon ion beam obtained by fragmentation of a primary beam of Pb i…

astro-ph2002★ 11 cited

Experimental study of a proximity focusing Cherenkov counter prototype for the AMS experiment

T. Thuillier, F. Malek, G. Boudoul +7

A study prototype of Proximity Focussing Ring Imaging Cherenkov counter has been built and tested with several radiators using separately cosmic-ray particles and 12C beam fragment…

physics.ins-det1998★ 7 cited

An Integrated Circuit for Signal Processing of the AMS RICH Photmultipliers Tubes

A. Barrau, L. Gallin-Martel, J. Pouxe +1

An analog integrated circuit has been designed, in a BiCMOS 0.8 micron technology, for the feasability study of the signal processing of the AMS RICH photomultiplier tubes. This lo…