72 citations · 338 across the 19 of their papers we have counts for
19 papers
Operation and performance of the Probe for Luminosity Measurement at LHCb
F. Alessio, S. Barsuk, C. Beigbeder +40
The Probe for LUminosity MEasurement (PLUME) detector is a dedicated luminosity monitor at the LHCb interaction point. It is a hodoscope comprising 48 Hamamatsu R760 photomultiplie…
PCIe400 generic readout board qualification test
Kevin Arnaud, Antoine Back, Daniel Charlet +13
The PCIe400 is a generic readout board designed for high-throughput data acquisition in future high-energy physics experiments. It interfaces up to 48 bidirectional links supportin…
Test-Beam and Simulation Studies Towards RPWELL-based DHCAL
Dan Shaked-Renous, Fernando Domingues Amaro, Purba Bhattacharya +11
Digital Hadronic Calorimeters (DHCAL) were suggested for future Colliders as part of the particle-flow concept. Though studied mainly with Resistive Plate Chambers (RPC), studies f…
Novel Resistive-Plate WELL sampling element for (S)DHCAL
S. Bressler, P. Bhattacharya, A. Breskin +10
Digital and Semi-Digital Hadronic Calorimeters (S)DHCAL were suggested for future Colliders as part of the particle-flow concept. Though studied mostly with RPC-based techniques, i…
The Compact Linear ee Collider (CLIC): Physics Potential
P. Roloff, R. Franceschini, U. Schnoor +1
The Compact Linear Collider, CLIC, is a proposed ee collider at the TeV scale whose physics potential ranges from high-precision measurements to extensive direct sensitivit…
The readout supervisor firmware for controlling the upgraded LHCb detector and readout system
Federico Alessio, Paolo Durante, Guillaume Vouters
In 2019, the LHCb experiment at CERN will undergo a major upgrade where its detector electronics and the entire readout system will be replaced. The goal is to read-out all events…
Updated baseline for a staged Compact Linear Collider
The CLIC, CLICdp collaborations, : +515
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to…
Construction and commissioning of a technological prototype of a high-granularity semi-digital hadronic calorimeter
G. Baulieu, M. Bedjidian, K. Belkadhi +43
A large prototype of 1.3m3 was designed and built as a demonstrator of the semi-digital hadronic calorimeter (SDHCAL) concept proposed for the future ILC experiments. The prototype…
Test in a beam of large-area Micromegas chambers for sampling calorimetry
C. Adloff, M. Chefdeville, A. Dalmaz +9
Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low…
The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers
C. Adloff, J. -J. Blaising, M. Chefdeville +210
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and de…
Shower development of particles with momenta from 1 to 10 GeV in the CALICE Scintillator-Tungsten HCAL
C. Adloff, J. -J. Blaising, M. Chefdeville +215
Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an collide…
Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron Calorimeter
C. Adloff, J. Blaha, J. -J. Blaising +169
Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, c…
Track segments in hadronic showers in a highly granular scintillator-steel hadron calorimeter
CALICE Collaboration, C. Adloff, J. -J. Blaising +205
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find tr…
Hadronic energy resolution of a highly granular scintillator-steel hadron calorimeter using software compensation techniques
CALICE Collaboration, C. Adloff, J. Blaha +163
The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS.…
Recent results of Micromegas sDHCAL with a new readout chip
C. Adloff, J. Blaha, J. -J. Blaising +13
Calorimetry at future linear colliders could be based on a particle flow approach where granularity is the key to high jet energy resolution. Among different technologies, Micromeg…
Micromegas for imaging hadronic calorimetry
C. Adloff, J. Blaha, S. Cap +12
The recent progress in R&D of the Micromegas detectors for hadronic calorimetry including new engineering-technical solutions, electronics development, and accompanying simulation…
Electromagnetic response of a highly granular hadronic calorimeter
C. Adloff, J. Blaha, J. -J. Blaising +164
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic c…
Status of the Micromegas semi-DHCAL
C. Adloff, J. Blaha, J. -J. Blaising +8
The activities towards the fabrication and test of a 1 m3 semi-digital hadronic calorime- ter are reviewed. The prototype sampling planes would consist of 1 m2 Micromegas chambers…
MICROMEGAS chambers for hadronic calorimetry at a future linear collider
C. Adloff, D. Attie, J. Blaha +15
Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO…