263 citations · 755 across the 38 of their papers we have counts for
23 papers · 1 filter
Application of LHC Gas Recuperation Systems for Methane Emission Control in Livestock Housing
Ilaria Vai, Francesco Alessandro Angiulli, Chiara Aimè +26
The CH4rLiE (CH4 Livestock Emission) project investigates the technical feasibility of adapting gas recovery systems from high-energy physics to mitigate methane (CH4) emissions in…
Capturing methane in a barn environment: the CH4 Livestock Emission (CH4rLiE) project
Francesco Alessandro Angiulli, Chiara Aimè, Maria Cristina Arena +18
The CH4 Livestock Emission (CH4rLiE) project explores the development of a prototype system for capturing methane emissions in barn environments, offering an alternative approach t…
Machine Learning based tool for CMS RPC currents quality monitoring
E. Shumka, A. Samalan, M. Tytgat +105
The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile…
RPC based tracking system at CERN GIF++ facility
K. Mota Amarilo, A. Samalan, M. Tytgat +105
With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for s…
MPGDs for tracking and Muon detection at future high energy physics colliders
K. Black, A. Colaleo, C. Aimè +61
In the next years, the energy and intensity frontiers of the experimental Particle Physics will be pushed forward with the upgrade of existing accelerators (LHC at CERN) and the en…
Upgrade of the CMS Resistive Plate Chambers for the High Luminosity LHC
A. Samalan, M. Tytgat, G. A. Alves +108
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb. The expected experime…
Effects of the electronic threshold on the performance of the RPC system of the CMS experiment
W. Elmetenawee
Resistive Plate Chambers have a very important role for muon triggering both in the barrel and in the endcap regions of the CMS experiment at the Large Hadron Collider (LHC). In or…
Towards a two-dimensional readout of the improved CMS Resistive Plate Chamber with a new front-end electronics
Sabino Meola
As part of the Compact Muon Solenoid experiment Phase-II upgrade program, new Resistive Plate Chambers will be installed in the forward region. High background conditions are expec…
Experiences from the RPC data taking during the CMS RUN-2
Mehar Ali Shah
The CMS experiment recorded 177.75 /fb of proton-proton collision data during the RUN-1 and RUN-2 data taking period. Successful data taking at increasing instantaneous luminositie…
CMS RPC Background -- Studies and Measurements
R. Hadjiiska, A. Samalan, M. Tytgat +106
The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used…
Aging Study on Resistive Plate Chambers of the CMS Muon Detector for HL-LHC
R. Aly
In the High Luminosity Large Hadron Collider (HL-LHC) program, during the next years, the instantaneous luminosity will increase up to 5 10 cm s which…
Improved-RPC for the CMS muon system upgrade for the HL-LHC
Priyanka Kumari
During Phase-2 of the LHC, known as the High Luminosity LHC (HL-LHC), the accelerator will increase its instantaneous luminosity to 5 10 cm s, deliver…
High rate, fast timing Glass RPC for the high η CMS muon detectors
F. Lagarde, M. Gouzevitch, I. Laktineh +108
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the ins…
High rate, fast timing Glass RPC for the high CMS muon detectors
Maxime Gouzevitch, François Lagarde, Imad Laktineh +16
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the ins…
Performance of Resistive Plate Chambers installed during the first long shutdown of the CMS experiment
M. Shopova, A. Aleksandrov, R. Hadjiiska +93
The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward…
Radiation Tests of Real-Sized Prototype RPCs for the Future CMS RPC Upscope
K. S. Lee, S. Choi, B. S. Hong +93
We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-η RPC triggers in the CMS. In the present study, we constructed…
Performance of the gas gain monitoring system of the CMS RPC muon detector
L. Benussi, S. Bianco, L. Passamonti +82
The RPC muon detector of the CMS experiment at the LHC (CERN, Geneva, Switzerland) is equipped with a Gas Gain Monitoring (GGM) system. A report on the stability of the system duri…
CMS RPC muon detector performance with 2010-2012 LHC data
G. Pugliese
The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers and Drif…
Radiation background with the CMS RPCs at the LHC
Silvia Costantini
The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of th…
Technical Design Report for the: PANDA Micro Vertex Detector
PANDA Collaboration, W. Erni, I. Keshelashvili +454
This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as clo…
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
The PANDA Collaboration, W. Erni, I. Keshelashvili +407
This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their antic…
Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)
PANDA Collaboration, W. Erni, I. Keshelashvili +407
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to m…
Detection of antihydrogen annihilations with a Si-micro-strip and pure CsI detector
I. Johnson
In 2002, the ATHENA collaboration reported the creation and detection of cold (~15 K) antihydrogen atoms [1]. The observation was based on the complete reconstruction of antihydrog…