activity
20012026
most citedThe Simons Observatory: Science goals and forecasts

1.5k citations · 5.8k across the 146 of their papers we have counts for

collaborators
Showing 2022Show all

15 papers · 1 filter

physics.ins-det2022★ 12 cited

A tabletop x-ray tomography instrument for nanometer-scale imaging: demonstration of the 1,000-element transition-edge sensor subarray

Paul Szypryt, Nathan Nakamura, Daniel T. Becker +28

We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial reso…

physics.ins-det2022★ 18 cited

Design of a 3000-pixel transition-edge sensor x-ray spectrometer for microcircuit tomography

Paul Szypryt, Douglas A. Bennett, William J. Boone +28

Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabr…

physics.ins-det2022★ 3 cited

Nanoscale Three-Dimensional Imaging of Integrated Circuits using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

Nathan Nakamura, Paul Szypryt, Amber L. Dagel +30

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but is difficult to implement due to competing requirements on X-ray flux an…

astro-ph.IM2022

A 50 mK test bench for demonstration of the readout chain of Athena/X-IFU

Florent Castellani, Sophie Beaumont, François Pajot +22

The X-IFU (X-ray Integral Field Unit) onboard the large ESA mission Athena (Advanced Telescope for High ENergy Astrophysics), planned to be launched in the mid 2030s, will be a cry…

astro-ph.IM2022★ 1 cited

CCAT-prime: The 850 GHz camera for Prime-Cam on FYST

Scott C. Chapman, Anthony I. Huber, Adrian K. Sinclair +23

The Fred Young Submillimeter Telescope (FYST) at the Cerro-Chajnantor Atacama Telescope prime (CCAT- prime) Facility will host Prime-Cam as a powerful, first generation camera with…

physics.ins-det2022★ 39 cited

SLAC Microresonator RF (SMuRF) Electronics: A tone-tracking readout system for superconducting microwave resonator arrays

Cyndia Yu, Zeeshan Ahmed, Josef C. Frisch +22

We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic det…

physics.ins-det2022★ 1 cited

The potential of microcalorimeter x-ray spectrometers for measurement of relative fluorescence-line intensities

J. W. Fowler, L. Miaja-Avila, G. C. O'Neil +3

We have previously used an array of cryogenic microcalorimeters with 4 eV energy resolution to measure emission-line profiles and energies of the characteristic L-shell x rays of f…

astro-ph.IM2022★ 1 cited

CCAT-prime: Design of the Mod-Cam receiver and 280 GHz MKID instrument module

Eve M. Vavagiakis, Cody J. Duell, Jason Austermann +33

Mod-Cam is a first light and commissioning instrument for the CCAT-prime project's six-meter aperture Fred Young Submillimeter Telescope (FYST), currently under construction at 560…

astro-ph.IM2022★ 2 cited

The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

Didier Barret, Vincent Albouys, Jan-Willem den Herder +296

The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile ob…

physics.ins-det2022★ 2 cited

Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV

Daikang Yan, Joel C. Weber, Tejas Guruswamy +25

Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the fe…

physics.ins-det2022★ 4 cited

Bandwidth and Aliasing in the Microwave SQUID Multiplexer

Cyndia Yu, Zeeshan Ahmed, Jake A. Connors +13

The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. Th…

astro-ph.IM2022★ 7 cited

The 511-CAM Mission: A Pointed 511 keV Gamma-Ray Telescope with a Focal Plane Detector Made of Stacked Transition Edge Sensor Microcalorimeter Arrays

Farzane Shirazi, Md. Arman Hossen, Daniel Becker +18

The 511 keV gamma-ray emission from the galactic center region may fully or partially originate from the annihilation of positrons from dark matter particles with electrons from th…

physics.ins-det2022★ 6 cited

Energy calibration of nonlinear microcalorimeters with uncertainty estimates from Gaussian process regression

J. W. Fowler, B. K. Alpert, G. C. O'Neil +2

The nonlinear energy response of cryogenic microcalorimeters is usually corrected through an empirical calibration. X-ray or gamma-ray emission lines of known shape and energy anch…

nucl-ex2022

Measuring the electron neutrino mass using the electron capture decay of 163Ho

Joel Ullom, Daniel Schmidt, Simon Bandler +14

While the mass differences between neutrino mass states are known, their absolute masses and mass hierarchy have not yet been determined. Determining the mass of neutrinos provides…

physics.ins-det2022★ 2 cited

Quantification of 242Pu with a Microcalorimeter Gamma Spectrometer

David J. Mercer, Ryan Winkler, Katrina E. Koehler +18

We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measu…