activity
20122020
most citedFirst high power pulsed tests of a dressed 325 MHz superconducting single spoke resonator at Fermilab

8 citations · 16 across the 8 of their papers we have counts for

collaborators
Showing physics.acc-phShow all

8 papers · 1 filter

physics.acc-ph2020★ 7 cited

Ring-Based Electron Cooling System for the EIC

V. Lebedev, S. Nagaitsev, A. Burov +5

This report describes a concept of an EIC cooling system, based on a proven induction linac technology with a dc electron beam. The system would operate in a full energy range of p…

physics.acc-ph2018

The FNAL Booster 2nd Harmonic RF Cavity

R. Madrak, J. Dey, K. Duel +11

A second harmonic RF cavity which uses perpendicularly biased garnet for frequency tuning is currently being constructed for use in the Fermilab Booster. The cavity will operate at…

physics.acc-ph2018

Garnet Ring Measurements For The Fermilab Booster 2nd Harmonic Cavity

J. Kuharik, J. Dey, K. Duel +9

A perpendicularly biased tuneable 2nd harmonic cavity is being constructed for use in the Fermilab Booster. The cavity's tuner uses National Magnetics AL800 garnet as the tuning me…

physics.acc-ph2017

Progress on the design of a perpendicularly biased 2nd harmonic cavity for the Fermilab Booster

R. L. Madrak, J. E. Dey, K. L. Duel +8

A perpendicularly biased 2nd harmonic cavity is being designed and built for the Fermilab Booster. Its purpose is to flatten the bucket at injection and thus change the longitudina…

physics.acc-ph2017

Static Magnetization Properties Of AL800 Garnet Material

J. Kuharik, R. Madrak, A. Makarov +4

A second harmonic tunable RF cavity is being developed for the Fermilab Booster. This device, which promises reduction of the particle beam loss at the injection, transition, and e…

physics.acc-ph2013★ 1 cited

High Gradient Tests of the Fermilab SSR1 Cavity

T. Khabiboulline, C. M. Ginsburg, I. Gonin +12

In Fermilab we are build and tested several superconducting Single Spoke Resonators (SSR1, β=0.22) which can be used for acceleration of low beta ions. Fist two cavities performed…

physics.acc-ph2012★ 8 cited

First high power pulsed tests of a dressed 325 MHz superconducting single spoke resonator at Fermilab

R. Madrak, J. Branlard, B. Chase +18

In the recently commissioned superconducting RF cavity test facility at Fermilab (SCTF), a 325 MHz, β=0.22 superconducting single-spoke resonator (SSR1) has been tested for the fir…

physics.acc-ph2012

CW RF system of the Project-X accelerator front end

T. Khabiboulline, S. Barbanotti, I. Gonin +3

Front end of a CW linac of the Project X contains an H source, an RFQ, a medium energy transport line with the beam chopper, and a SC low-beta linac that accelerates H- from 2.5 Me…