18 citations · 32 across the 3 of their papers we have counts for
3 papers
physics.ins-det2012★ 12 cited
Development of a custom on-line ultrasonic vapour analyzer/flowmeter for the ATLAS inner detector, with application to gaseous tracking and Cherenkov detectors
R. Bates, M. Battistin, S. Berry +24
Precision sound velocity measurements can simultaneously determine binary gas composition and flow. We have developed an analyzer with custom electronics, currently in use in the A…
physics.ins-det2012★ 18 cited
A combined ultrasonic flow meter and binary vapour mixture analyzer for the ATLAS silicon tracker
R. Bates, M. Battistin, S. Berry +25
An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) evaporative coolant to a blend containing 10-25% of C2F6 (hexaflu…
physics.acc-ph2012★ 2 cited
A Combine On-Line Acoustic Flowmeter and Fluorocarbon Coolant Mixture Analyzer for The ATLAS Silicon Tracker
A. Bitadze, R. Bates, M. Battistin +19
An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) to a blend containing 10-30% of C2F6 (hexafluoro-ethane) to reduc…