activity
20122015
most citedNEXT-100 Technical Design Report (TDR). Executive Summary

104 citations · 421 across the 15 of their papers we have counts for

collaborators

15 papers

physics.ins-det2015★ 6 cited

First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment

NEXT Collaboration, P. Ferrario, A. Laing +67

The NEXT experiment aims to observe the neutrinoless double beta decay of xenon in a high-pressure Xe136 gas TPC using electroluminescence (EL) to amplify the signal from ionizatio…

physics.ins-det2015★ 12 cited

Radon and material radiopurity assessment for the NEXT double beta decay experiment

S. Cebrián, J. Pérez, I. Bandac +67

The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at…

physics.ins-det2015★ 42 cited

Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atmospheres

Diego Gonzalez-Diaz, V. Alvarez, F. I. G. Borges +80

We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with t…

physics.ins-det2014★ 14 cited

An improved measurement of electron-ion recombination in high-pressure xenon gas

NEXT Collaboration, L. Serra, M. Sorel +64

We report on results obtained with the NEXT-DEMO prototype of the NEXT-100 high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration source. Comp…

physics.ins-det2014★ 2 cited

Results of the material screening program of the NEXT experiment

T. Dafni, V. Alvarez, I. Bandac +67

The 'Neutrino Experiment with a Xenon TPC (NEXT)', intended to investigate neutrinoless double beta decay, requires extremely low background levels. An extensive material screening…

physics.ins-det2014★ 36 cited

Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment

S. Cebrián, J. Pérez, I. Bandac +68

The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of p…

physics.ins-det2014★ 17 cited

Ionization and scintillation of nuclear recoils in gaseous xenon

J. Renner, V. M. Gehman, A. Goldschmidt +75

Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber…

physics.ins-det2013★ 15 cited

Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture

NEXT Collaboration, V. Álvarez, F. Aznar +82

A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ~35 cm drift 28 cm diameter, it constitutes the larg…

physics.ins-det2013★ 29 cited

Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy -rays

The NEXT collaboration, V. Alvarez, F. I. G. M. Borges +87

NEXT-MM is a general-purpose high pressure (10 bar, l active volume) Xenon-based TPC, read out in charge mode with an 8 cm 8 cm-segmented 700 cm plane (1152 ch…

physics.ins-det2013★ 39 cited

Operation and first results of the NEXT-DEMO prototype using a silicon photomultiplier tracking array

The NEXT Collaboration, V. Álvarez, F. I. G. Borges +75

NEXT-DEMO is a high-pressure xenon gas TPC which acts as a technological test-bed and demonstrator for the NEXT-100 neutrinoless double beta decay experiment. In its current config…

physics.ins-det2012★ 40 cited

Ionization and scintillation response of high-pressure xenon gas to alpha particles

NEXT Collaboration, V. Álvarez, F. I. G. M. Borges +70

High-pressure xenon gas is an attractive detection medium for a variety of applications in fundamental and applied physics. In this paper we study the ionization and scintillation…

physics.ins-det2012★ 43 cited

Radiopurity control in the NEXT-100 double beta decay experiment: procedures and initial measurements

V. Alvarez, I. Bandac, A. Bettini +77

The Neutrino Experiment with a Xenon TPC (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds…

physics.ins-det2012★ 3 cited

Design and characterization of the SiPM tracking system of NEXT-DEMO, a demonstrator prototype of the NEXT-100 experiment

NEXT Collaboration, V. Álvarez, M. Ball +86

NEXT-100 experiment aims at searching the neutrinoless double-beta decay of the Xe-136 isotope using a TPC filled with a 100 kg of high-pressure gaseous xenon, with 90% isotopic en…

physics.ins-det2012★ 104 cited

NEXT-100 Technical Design Report (TDR). Executive Summary

NEXT Collaboration, V. Álvarez, F. I. G. M. Borges +84

In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (bbonu) in Xe-136 at the Laboratorio Subterraneo de Canf…

physics.ins-det2012★ 19 cited

SiPMs coated with TPB : coating protocol and characterization for NEXT

V. Álvarez, J. Agramunt, M. Ball +91

Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless ββ decay experiment which uses a high pressure gaseous xenon time p…