activity
20122015
most citedThe Upgrade of the CMS RPC System during the First LHC Long Shutdown

13 citations · 53 across the 10 of their papers we have counts for

collaborators

11 papers

physics.ins-det2015

A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

D. Abbaneo, M. Abbas, M. Abbrescia +153

We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to…

physics.ins-det2015★ 2 cited

Fiber Bragg Grating (FBG) sensors as flatness and mechanical stretching sensors

D. Abbaneo, M. Abbas, M. Abbrescia +153

A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and…

physics.ins-det2014★ 3 cited

Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

D. Abbaneo, M. Abbas, M. Abbrescia +134

Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for…

physics.ins-det2014★ 3 cited

CMS RPC muon detector performance with 2010-2012 LHC data

G. Pugliese

The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers and Drif…

physics.ins-det2014

Radiation background with the CMS RPCs at the LHC

Silvia Costantini

The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of th…

physics.ins-det2013★ 1 cited

Potential Impact of a New GEM-based Detector on CMS Triggering

A. Castaneda

With the increases in the LHC instantaneous luminosity, maintaining effective triggering and avoiding dead time will become especially challenging. As the sensitivity of many physi…

physics.ins-det2013★ 1 cited

Simulation of the CMS Resistive Plate Chambers

R. Hadjiiska, L. Litov, B. Pavlov +61

The Resistive Plate Chamber (RPC) muon subsystem contributes significantly to the formation of the trigger decision and reconstruction of the muon trajectory parameters. Simulation…

physics.ins-det2012★ 7 cited

A study of gas contaminants and interaction with materials in RPC closed loop systems

S. Colafranceschi, R. Aurilio, L. Benussi +18

Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this pape…

physics.ins-det2012★ 11 cited

Uniformity and Stability of the CMS RPC Detector at the LHC

S. Costantini, K. Beernaert, A. Cimmino +60

The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of th…

physics.ins-det2012★ 13 cited

The Upgrade of the CMS RPC System during the First LHC Long Shutdown

M. Tytgat, A. Marinov, P. Verwilligen +31

The CMS muon system includes in both the barrel and endcap region Resistive Plate Chambers (RPC). They mainly serve as trigger detectors and also improve the reconstruction of muon…

physics.ins-det2012★ 12 cited

CMS Resistive Plate Chamber overview, from the present system to the upgrade phase I

P. Paolucci, R. Hadjiiska, L. Litov +60

University of Sofia, Faculty of Physics, Atomic Physics Department, 5, James Bourchier Boulevard, BG-1164 Sofia, Bulgaria Ghent University, Department of Physics and Astronomy, Pro…