3 citations · 3 across the 4 of their papers we have counts for
4 papers
Study of the neutron dose equivalent at the HIRFL deep tumor therapy terminal
Jun-Kui Xu, You-Wu Su, Wu-Yuan Li +5
The secondary neutron fields at the deep tumor therapy terminal at HIRFL (Heavy Ion Research Facility in Lanzhou) were investigated. The distributions of neutron ambient dose equiv…
Experimental Study of residual radioactivity induced in SFC Electrostatic Deflector
Chong Xu, Wu-Yuan Li, Jun-Kui Xu +4
Electrostatic Deflector, one of the key components of SFC accelerator at IMP, is easily activated in the long-term running of HIRFL due to the bombardment with losing ions. The lev…
Neutron Dose measurement in the carbon ion therapy area at HIRFL (IMP) as 12C ions with energies from 165 to 350MeV/u
Jun-Kui Xu, Wu-Yuan Li, Wei-Wei Yan +5
The neutron dose distributions on observation distances and on observation angles were measured using a Wendi-II neutron dose-meter at the deep tumor therapy terminal at HIRFL (Hea…
Simulation of induced radioactivity for Heavy Ion Medical Machine
Xu Jun-Kui, Su You-Wu, Li Wu-Yuan +5
For radiation protection and environmental impact assessment purpose, the radioactivity induced by carbon ion of Heavy Ion Medical Machine (HIMM) was studied. Radionuclides in acce…