activity
20132021
most citedX-ray detection with Micromegas with background levels below 10 keVcms

26 citations · 64 across the 7 of their papers we have counts for

collaborators

8 papers

physics.ins-det2021★ 9 cited

The large inner Micromegas modules for the Atlas Muon Spectrometer Upgrade: construction, quality control and characterization

J. Allard, M. Anfreville, N. Andari +71

The steadily increasing luminosity of the LHC requires an upgrade with high-rate and high-resolution detector technology for the inner end cap of the ATLAS muon spectrometer: the N…

physics.ins-det2015★ 2 cited

Neutron spectroscopy with the Spherical Proportional Counter

E. Bougamont, A. Dastgheibi, J. Derre +11

A novel large volume spherical proportional counter, recently developed, is used for neutron measurements. Gas mixtures of with and pure are studied fo…

physics.ins-det2015★ 3 cited

Low Background Micromegas in CAST

J. G. Garza, S. Aune, D. Calvet +22

Solar axions could be converted into x-rays inside the strong magnetic field of an axion helioscope, triggering the detection of this elusive particle. Low background x-ray detecto…

astro-ph.IM2015

Lowering the background level and the energy threshold of Micromegas x-ray detectors for axion searches

F. J. Iguaz, S. Aune, F. Aznar +14

Axion helioscopes search for solar axions by their conversion in x-rays in the presence of high magnetic fields. The use of low background x-ray detectors is an essential component…

astro-ph.IM2014★ 5 cited

Background optimization for a new spherical gas detector for very light WIMP detection

Ali Dastgheibi-Fard, I. Giomataris, G. Gerbierb +13

The Spherical gaseous detector (or Spherical Proportional Counter, SPC) is a novel type of par- ticle detector, with a broad range of applications. Its main features include a very…

astro-ph.IM2014★ 19 cited

NEWS : a new spherical gas detector for very low mass WIMP detection

G. Gerbier, I. Giomataris, P. Magnier +10

The main characteristics of a new concept of spherical gaseous detectors, with some details on its operation are first given. The very low energy threshold of such detector has led…

physics.ins-det2013★ 26 cited

X-ray detection with Micromegas with background levels below 10 keVcms

S. Aune, F. Aznar, D. Calvet +26

Micromegas detectors are an optimum technological choice for the detection of low energy x-rays. The low background techniques applied to these detectors yielded remarkable backgro…

physics.ins-det2013

Low background x-ray detection with Micromegas for axion research

S. Aune, J. F. Castel, T. Dafni +23

Axion helioscopes aim at the detection of solar axions through their conversion into x-rays in laboratory magnetic fields. The use of low background x-ray detectors is an essential…