164 citations · 2.9k across the 95 of their papers we have counts for
23 papers · 1 filter
Description and stability of a RPC-based calorimeter in electromagnetic and hadronic shower environments
D. Boumediene, V. Francais, J. Apostolakis +36
The CALICE Semi-Digital Hadron Calorimeter technological prototype completed in 2011 is a sampling calorimeter using Glass Resistive Plate Chamber (GRPC) detectors as the active me…
Performance study of SKIROC2/A ASIC for ILD Si-W ECAL
T. Suehara, I. Sekiya, S. Callier +11
The ILD Si-W ECAL is a sampling calorimeter with tungsten absorber and highly segmented silicon layers for the International Large Detector (ILD), one of the two detector concepts…
Construction and Response of a Highly Granular Scintillator-based Electromagnetic Calorimeter
CALICE collaboration, J. Repond, L. Xia +78
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 depth and $180 \t…
Tracking within Hadronic Showers in the CALICE SDHCAL prototype using a Hough Transform Technique
The CALICE Collaboration
The high granularity of the CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) provides the capability to reveal the track segments present in hadronic showers. These segments are t…
Testing Hadronic Interaction Models using a Highly Granular Silicon-Tungsten Calorimeter
Naomi van der Kolk
The CALICE collaboration has published a detailed study of hadronic interactions using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter (S…
Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter
The CALICE collaboration, M. Chefdeville, Y. Karyotakis +178
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue had…
Experimental Tests of Particle Flow Calorimetry
Felix Sefkow, Andy White, Kiyotomo Kawagoe +2
Precision physics at future colliders requires highly granular calorimeters to support the Particle Flow Approach for event reconstruction. This article presents a review of about…
Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter
The CALICE Collaboration, B. Bilki, J. Repond +169
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNA…
Testing Hadronic Interaction Models using a Highly Granular Silicon-Tungsten Calorimeter
The CALICE Collaboration, B. Bilki, J. Repond +148
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selec…
The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers
C. Adloff, J. -J. Blaising, M. Chefdeville +210
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and de…
A study of silicon sensor for ILD ECAL
Tatsuhiko Tomita, Shion Chen, Daniel Jeans +9
The International Large Detector (ILD) is a proposed detector for the International Linear Collider (ILC). It has been designed to achieve an excellent jet energy resolution by usi…
Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
CALICE Collaboration, K. Francis, J. Repond +191
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 pl…
Shower development of particles with momenta from 1 to 10 GeV in the CALICE Scintillator-Tungsten HCAL
C. Adloff, J. -J. Blaising, M. Chefdeville +215
Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an collide…
Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron Calorimeter
C. Adloff, J. Blaha, J. -J. Blaising +169
Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, c…
Track segments in hadronic showers in a highly granular scintillator-steel hadron calorimeter
CALICE Collaboration, C. Adloff, J. -J. Blaising +205
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find tr…
Construction and performance of a silicon photomultiplier/extruded scintillator tail-catcher and muon-tracker
The CALICE Collaboration
A prototype module for an International Linear Collider (ILC) detector was built, installed, and tested between 2006 and 2009 at CERN and Fermilab as part of the CALICE test beam p…
Tests of a particle flow algorithm with CALICE test beam data
The CALICE Collaboration
The studies presented in this paper provide a first experimental test of the Particle Flow Algorithm (PFA) concept using data recorded in high granularity calorimeters. Pairs of ov…
Electromagnetic response of a highly granular hadronic calorimeter
C. Adloff, J. Blaha, J. -J. Blaising +164
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic c…
Test Beams Summary
Kiyotomo Kawagoe
ILC detectors are required to have unprecedented precision. Achieving this requires significant investment for test beam activities to complete the detector R&D needed, to test pro…
Status of Simulation Tools for the ILD ScECAL
Katsushige Kotera, Marc Anduze, Vincent Boudry +9
The scintillator-strip electromagnetic calorimeter (ScECAL) is one of the calorimeter technic for the ILC. To achieve the fine granularity from the strip-segmented layers the strip…
Construction and Commissioning of the CALICE Analog Hadron Calorimeter Prototype
C. Adloff, Y. Karyotakis, J. Repond +225
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consist…
Response of the CALICE Si-W Electromagnetic Calorimeter Physics Prototype to Electrons
CALICE Collaboration
A prototype Silicon-Tungsten electromagnetic calorimeter (ECAL) for an International Linear Collider (ILC) detector was installed and tested during summer and autumn 2006 at CERN.…
The ATLAS Level-1 Trigger: Status of the System and First Results from Cosmic-Ray Data
David Berge
The ATLAS detector at CERN's Large Hadron Collider (LHC) will be exposed to proton-proton collisions from beams crossing at 40 MHz. At the design luminosity of 10^34 cm^-2 s^-1 the…