29 citations · 57 across the 2 of their papers we have counts for
2 papers
physics.ins-det2013★ 29 cited
Next generation KATRIN high precision voltage divider for voltages up to 65kV
S. Bauer, R. Berendes, F. Hochschulz +5
The KATRIN (KArlsruhe TRItium Neutrino) experiment aims to determine the mass of the electron antineutrino with a sensitivity of 200meV by precisely measuring the electron spectrum…
physics.atom-ph2011★ 28 cited
Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy
A. Krieger, Ch. Geppert, R. Catherall +9
A high-voltage divider with accuracy at the ppm level and collinear laser spectroscopy were used to calibrate the highvoltage installation at the radioactive ion beam facility ISOL…