activity
20102020
most citedNew limit on Lorentz and CPT violating neutron spin interactions using a free precession 3He-129Xe co-magnetometer

188 citations · 484 across the 11 of their papers we have counts for

collaborators

11 papers

physics.atom-ph2020★ 5 cited

Polarization-Dependent Disappearance of a Resonance Signal -- Indication for Optical Pumping in a Storage Ring?

W. Nörtershäuser, A. Surzhykov, R. Sánchez +10

We report on laser spectroscopic measurements on Li ions in the experimental storage ring ESR at the GSI Helmholtz Centre for Heavy Ion Research. Driving the $2s\,^3\!{S}_1\;(F…

physics.atom-ph2019★ 52 cited

Measurement of the Permanent Electric Dipole Moment of the Xe Atom

F. Allmendinger, I. Engin, W. Heil +7

We report on a new measurement of the CP-violating permanent Electric Dipole Moment (EDM) of the neutral Xe atom. Our experimental approach is based on the detection of the…

physics.ins-det2017★ 17 cited

Upgrade of the ultracold neutron source at the pulsed reactor TRIGA Mainz

Jan Kahlenberg, Dieter Ries, Kim Ulrike Ross +13

The performance of the upgraded solid deuterium ultracold neutron source at the pulsed reactor TRIGA Mainz is described. The current configuration stage comprises the installation…

physics.ins-det2016★ 55 cited

Comparison of ultracold neutron sources for fundamental physics measurements

G. Bison, M. Daum, K. Kirch +20

Ultracold neutrons (UCNs) are key for precision studies of fundamental parameters of the neutron and in searches for new CP violating processes or exotic interactions beyond the St…

hep-ph2016★ 1 cited

Limit on Lorentz-Invariance- and CPT-Violating Neutron Spin Interactions Using a He-Xe Comagnetometer

Fabian Allmendinger, Ulrich Schmidt, Werner Heil +2

We performed a search for a Lorentz-invariance- and CPT-violating coupling of the He and Xe nuclear spins to posited background fields. Our experimental approach is to…

physics.atom-ph2014★ 80 cited

Test of Time Dilation Using Stored Li+ Ions as Clocks at Relativistic Speed

Benjamin Botermann, Dennis Bing, Christopher Geppert +14

We present the concluding result from an Ives-Stilwell-type time dilation experiment using 7Li+ ions confined at a velocity of beta = v/c = 0.338 in the storage ring ESR at Darmsta…

gr-qc2013★ 188 cited

New limit on Lorentz and CPT violating neutron spin interactions using a free precession 3He-129Xe co-magnetometer

F. Allmendinger, W. Heil, S. Karpuk +6

We report on the search for a CPT and Lorentz invariance violating coupling of the 3He and 129Xe nuclear spins (each largely determined by a valence neutron) to background tensor f…

physics.atom-ph2013★ 2 cited

Modern Ives-Stilwell Experiments At Storage Rings: Large Boosts Meet High Precision

G. Gwinner, B. Botermann, C. Geppert +14

We give a brief overview of time dilation tests using high-resolution laser spectroscopy at heavy-ion storage rings. We reflect on the various methods used to eliminate the first-o…

physics.atom-ph2011★ 8 cited

Comment on "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions"

G. Saathoff, S. Reinhardt, R. Holzwarth +14

In an article "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions" by S. Devasia [arXiv:1003.2970v1], our recent Doppler shift experiments on fast…

gr-qc2010★ 73 cited

Limit on Lorentz and CPT violation of the bound Neutron Using a Free Precession 3He/129Xe co-magnetometer

C. Gemmel, W. Heil, S. Karpuk +11

We report on the search for Lorentz violating sidereal variations of the frequency difference of co-located spin-species while the Earth and hence the laboratory reference frame ro…

hep-ph2010★ 3 cited

Test of Lorentz Symmetry by using a 3He/129Xe Co-Magnetometer

K. Tullney, C. Gemmel, W. Heil +11

To test Lorentz symmetry we used a 3He/129Xe co-magnetometer. We will give a short summary of our experimental setup and the results of our latest measurements. We obtained prelimi…