most citedGPU-based Low Dose CT Reconstruction via Edge-preserving Total Variation Regularization

399 citations · 2.2k across the 32 of their papers we have counts for

collaborators
Showing 2012Show all

7 papers · 1 filter

physics.med-ph2012★ 59 cited

Extracting respiratory signals from thoracic cone beam CT projections

Hao Yan, Xiaoyu Wang, Wotao Yin +6

Patient respiratory signal associated with the cone beam CT (CBCT) projections is important for lung cancer radiotherapy. In contrast to monitoring an external surrogate of respira…

physics.med-ph2012★ 29 cited

Effect of Statistical Fluctuation in Monte Carlo Based Photon Beam Dose Calculation on Gamma Index Evaluation

Yan Jiang Graves, Xun Jia, Steve B. Jiang

The gamma-index test has been commonly adopted to quantify the degree of agreement between a reference dose distribution and an evaluation dose distribution. Monte Carlo (MC) simul…

physics.med-ph2012★ 125 cited

A GPU Tool for Efficient, Accurate, and Realistic Simulation of Cone Beam CT Projections

Xun Jia, Hao Yan, Laura Cervino +2

Simulation of x-ray projection images plays an important role in cone beam CT (CBCT) related research projects. A projection image contains primary signal, scatter signal, and nois…

physics.med-ph2012★ 3 cited

CT to Cone-beam CT Deformable Registration With Simultaneous Intensity Correction

Xin Zhen, Xuejun Gu, Hao Yan +3

Computed tomography (CT) to cone-beam computed tomography (CBCT) deformable image registration (DIR) is a crucial step in adaptive radiation therapy. Current intensity-based regist…

physics.med-ph2012★ 21 cited

Optimal Surface Marker Locations for Tumor Motion Estimation in Lung Cancer Radiotherapy

Bin Dong, Yan Jiang Graves, Xun Jia +1

Using fiducial markers on patient's body surface to predict the tumor location is a widely used approach in lung cancer radiotherapy. The purpose of this work is to propose an algo…

physics.med-ph2012★ 88 cited

A comprehensive study on the relationship between image quality and imaging dose in low-dose cone beam CT

Hao Yan, Laura Cervino, Xun Jia +1

While compressed sensing (CS) based reconstructions have been developed for low-dose CBCT, a clear understanding on the relationship between the image quality and imaging dose at l…

physics.med-ph2012★ 77 cited

Four-dimensional Cone Beam CT Reconstruction and Enhancement using a Temporal Non-Local Means Method

Xun Jia, Zhen Tian, Yifei Lou +2

Four-dimensional Cone Beam Computed Tomography (4D-CBCT) has been developed to provide respiratory phase resolved volumetric imaging in image guided radiation therapy (IGRT). Inade…