activity
20112022
most citedIndication for the disappearance of reactor electron antineutrinos in the Double Chooz experiment

1.2k citations · 1.7k across the 8 of their papers we have counts for

collaborators

8 papers

physics.ins-det2022★ 1 cited

The Double Chooz antineutrino detectors

Double Chooz Collaboration, H. de Kerret, Y. Abe +247

This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were meas…

physics.ins-det2013★ 18 cited

Afterpulse Measurements of R7081 Photomultipliers for the Double Chooz Experiment

Julia Haser, Florian Kaether, Conradin Langbrandtner +7

We present the results of afterpulse measurements performed as qualification test for 473 inner detector photomultipliers of the Double Chooz experiment. The measurements include t…

physics.ins-det2012★ 1 cited

PMT Test Facility at MPIK Heidelberg and Double Chooz Super Vertical Slice

J. Haser, F. Kaether, C. Langbrandtner +3

Proceedings supplement for conference poster at Neutrino 2010, Athens, Greece.

hep-ex2012★ 34 cited

Direct Measurement of Backgrounds using Reactor-Off Data in Double Chooz

Y. Abe, C. Aberle, J. C. dos Anjos +170

Double Chooz is unique among modern reactor-based neutrino experiments studying disappearance in that data can be collected with all reactors off. In this paper, we pres…

hep-ex2012★ 374 cited

Reactor electron antineutrino disappearance in the Double Chooz experiment

Y. Abe, C. Aberle, J. C. dos Anjos +162

The Double Chooz experiment has observed 8,249 candidate electron antineutrino events in 227.93 live days with 33.71 GW-ton-years (reactor power x detector mass x livetime) exposur…

physics.ins-det2012★ 25 cited

Transit Time and Charge Correlations of Single Photoelectron Events in R7081 PMTs

Florian Kaether, Conradin Langbrandtner

During the calibration phase of the photomultiplier tubes (PMT) for the Double Chooz experiment the PMT response to light with single photoelectron (SPE) intensity was analysed. Wi…

hep-ex2011★ 1.2k cited

Indication for the disappearance of reactor electron antineutrinos in the Double Chooz experiment

Y. Abe, C. Aberle, T. Akiri +182

The Double Chooz Experiment presents an indication of reactor electron antineutrino disappearance consistent with neutrino oscillations. A ratio of 0.944 0.016 (stat) 0…

physics.ins-det2011★ 38 cited

Qualification Tests of 474 Photomultiplier Tubes for the Inner Detector of the Double Chooz Experiment

C. Bauer, E. Borger, R. Hofacker +9

The hemispherical 10" photomultiplier tube (PMT) R7081 from Hamamatsu Photonics K.K. (HPK) is used in various experiments in particle and astroparticle physics. We describe the tes…